Specifications
Floor/ceiling-suspended dual type
Model name
FLXS25BVMA
Power supply
Front grille colour
Cooling
126 (268)
Airflow rate
/s
(H)
Heating
(cfm)
153 (325)
Cooling
37/31/28
Sound level
dB (A)
(H/L/SL)
Heating
37/31/29
Cooling
53
Sound power
dB (A)
level (H)
Heating
53
Fan speed
Temperature control
Dimensions (H x W x D)
mm
Machine weight
kg
16
Liquid (flare)
Piping
Gas (flare)
ø9.5
connections
mm
Drain
Heat insulation
Compact multi flow ceiling-mounted cassette type
Cooling only
Model name
FFQ25BV1B
FFQ35BV1B
Power supply
Cooling
150 (318)
167 (353)
Airflow rate
/s
(H)
(cfm)
Heating
Sound level*
Cooling
29.5/24.5
32/25
dB (A)
(H/L)
Heating
Sound power
Cooling
46.5
49
dB (A)
level (H)
Heating
Fan speed
Temperature control
Unit dimensions (H x W x D)
mm
Machine weight
kg
Liquid (flare)
Piping
Gas (flare)
mm
ø9.5
connections
Drain
Heat insulation
Model
Panel
Colour
(option)
Dimensions (H x W x D)
mm
Weight
kg
*
Note:
Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
Measurement conditions
1. Cooling operation data is based on the following conditions: indoor temp. 27
2. Heating operation data is based on the following conditions: indoor temp. 20
3. Sound levels are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of ambient conditions.
25
FLXS35GVMA
FLXS50GVMA
FLXS60GVMA
1 phase, 220-240 V/220-230 V, 50/60 Hz
Almond white
143 (304)
190 (402)
200 (424)
163 (346)
202 (427)
213 (452)
38/32/29
47/39/36
48/41/39
39/33/30
46/35/33
47/37/34
54
63
55
62
5 steps, quiet and automatic
Microcomputer control
490 x 1,050 x 200
17
ø6.4
ø12.7
ø18.0
Both liquid and gas pipes
Heat pump
FFQ50BV1B
FFQ60BV1B
FFQ25BV1B
FFQ35BV1B
FFQ50BV1B
1 phase, 220-240 V, 50 Hz
200 (424)
250 (530)
150 (318)
167 (353)
200 (424)
150 (318)
167 (353)
200 (424)
36/27
41/32
29.5/24.5
32/25
36/27
29.5/24.5
32/25
36/27
53
58
46.5
49
53
46.5
49
53
2 steps
Microcomputer control
286 x 575 x 575
17.5
ø6.4
ø12.7
ø9.5
VP20 (External Dia. 26/Internal Dia. 20)
Both liquid and gas pipes
BYFQ60B8W1
White
55 x 700 x 700
2.7
°
CDB, 19
°
CWB; outdoor temp. 35
°
CDB; piping length 5 m.
°
CDB; outdoor temp. 7
°
CDB, 6
°
CWB; piping length 5 m.

Options

No.
1
Air direction adjustment grille
2
Drain plug
Notes: *1. One set includes 5 pieces for 5 units.
*2. One set includes 1 piece for 1 unit.
64
63
No.
1
Wired remote controller*
Wired remote controller
2
cord
5-room centralised controller*
3
FFQ60BV1B
Wiring adaptor for time clock/remote controller*
4
(Normal open pulse contact/normal open contact)
250 (530)
Titanium apatite photocatalytic air-purifying filter*
5
250 (530)
6
Photocatalytic deodorising filter with frame*
41/32
Photocatalytic deodorising filter without frame*
7
41/32
8
Air-purifying filter with frame*
58
Air-purifying filter without frame*
9
58
Wireless remote controller loss prevention chain
10
11
Suction grille
Insulation kit for high humidity
12
Notes: *1. 3 m (BRCW901A03) or 8 m (BRCW901A08) length wired remote controller cord is necessary.
*2. A wiring adaptor (KRP413AB1S) is also required for each indoor unit.
*3. Time clock and other devices should be obtained locally.
ø12.7
*4. Filter is a standard accessory. It should be replaced approximately every 3 years.
*5. The photocatalytic deodorising filter is a standard accessory. It can be reused indefinitely if it is exposed to direct sunlight once every 6 months.
This accessory is only required if the original filter is damaged or lost, etc.
*6. The air-purifying filter is a standard accessory. It should be replaced approximately once every 3 months. This accessory is required for the replacement of filters.
Wired remote
controller
BRC944B2
No.
1
Decoration panel
2
Remote controller
3
Adaptor for wiring
*
2
4
Wiring adaptor for electrical appendices
5
Installation box for adaptor PCB
6
Remote sensor (for indoor temperature)
7
Replacement long-life filter
8
Fresh air intake kit
9
Sealing member of air discharge outlet
10
Panel spacer
Notes: *1. Wiring for wired remote controller should be obtained locally.
*2. Installation box for adaptor PCB (KRP1BA101) is necessary.
No.
1
Central remote controller*
2
Unified on/off controller*
3
Schedule timer*
4
Interface adaptor for DIII-NET use
Note: * Interface adaptor for DIII-NET use (KRP928BB2S) is also required for each indoor unit.
Outdoor unit
Item
3MXS52L
3MKS58L
3MXS68L
KPW945A4
KKP937A4*
1
Air direction adjustment grille
KPW945A4
Indoor unit
Wall-mounted type
Item
CDK(X)S25/35EA
1
BRC944B2
Length 3 m (shielded wire)
BRCW901A03
Length 8 m (shielded wire)
BRCW901A08
2
3
4
KAF970A46
5
5
6
6
KKF910A4
KDT25N32
5-room centralised
Titanium apatite photocatalytic
controller
air-purifying filter
KRC72
KAF970A46
Item
Compact multi flow ceiling-mounted cassette type
Wired type
*
1
Heat pump use
Wireless type
Cooling only use
*
2
Direct installation type
Control system
Wall-mounted type
Duct-connected type
Item
Unified on/off controller
Central remote controller
DCS301BA61
DCS302CA61
Options
3MKS68L
4MXS80L
4MKS80L 5MXS100L 5MKS100L
KPW5E112
KKP945A4*
2
Drain plug
KKP937A4
Duct-connected type
Floor-standing
Floor/ceiling-
type
suspended dual type
C(F)DK(X)S25-50C C(F)DK(X)S60C
KRC72
KRP413AB1S
KAF968A42
KAZ917B41
KAZ917B42
KAF925B41
KAF925B42
KKF917A4
KKF910A4
KKF917A4
KDGF19A45
KDT25N50
KDT25N63
Remote controller loss
prevention chain
KKF917A4
BYFQ60B8W1
BRC1C61
BRC7E530W
BRC7E531W
KRP1BA57
KRP4AA53
KRP1BA101
KRCS01-1B
KAFQ441BA60
KDDQ44XA60
KDBH44BA60
KDBQ44BA60A
Floor-standing type
Floor/ceiling-suspended dual type
DCS302CA61
DCS301BA61
DST301BA61
KRP928BB2S