Electrical Installation - Maytag MED7000XG0 Installation Instructions Manual

Electric dryer
Table of Contents

Advertisement

ELECTRIC
INS
LATION
For power
supply cord installations:
Fire Hazard
Use a new UL listed 30 amp power supply cord.
Use a UL listed strain relief.
Disconnect power before making electrical connections.
Connect neutral
wire (white or center wire) to center
terminal
(silver).
Ground wire (green or bare wire) must be connected to
green ground connector.
Connect remaining 2 supply wires to remaining
2 terminals
(gold).
Securely tighten all electrical connections.
Failure to do so can result in death, fire, or
electrical shock.
Before you start: disconnect
power.
1, Choose
electrical
connection
type
Power supply cord 4-wire receptacle
(NEMA Type 14-30R).
Go to Power Supply Cord Connection.
Power supply cord 3-wire receptacle
(NEMA Type 10-30R).
Go to Power Supply Cord Connection.
4-wire direct connection:
Go to Direct Wire Connection.
3-wire direct connection:
Go to Direct Wire Connection.
NOTE: If local codes do not permit connection of a
cabinet-ground
conductor to neutral wire, go to "Optional
3-wire connection".
This connection may be used with
either a power supply cord or a direct wire connection.
For direct wire installations:
Fire Hazard
Use 10 gauge copper wire.
Use a UL listed strain relief.
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center
terminal
(silver).
Ground wire (green or bare wire) must be connected to
green ground connector.
Connect remaining 2 supply wires to remaining
2 terminals
(gold).
Securely tighten all electrical connections.
Failure to do so can result in death, fire, or
electrical shock.
Remove hold-down screw and terminal block cover.