KitchenAid KDRP407HSS12 Installation Instructions Manual page 9

30" (76.2 cm) commercial style dual fuel range with self-cleaning thermal/convection oven
Hide thumbs Also See for KDRP407HSS12:
Table of Contents

Advertisement

Available languages

Available languages

I
> ...... '"_
==I_=.: , ,;= _
I!II klt.]I ell
.......
i
1.
2.
Tip Over Hazard
A child or adult can tip the range and be killed.
Connect anti-tip bracket to wail behind range.
Reconnect the anti-tip bracket, if the range is moved.
Failure to follow these instructions can result in death
or serious burns to children and adults.
Choose the correct anti-tip bracket for your installation.
If the wall behind the range has no baseboard or has a
baseboard up to 3/8"(0.95 cm) thick, use the shorter
1" (2.5 cm) anti-tip bracket.
If the wall behind the range has a baseboard thicker than
3/8"(0.95 cm), use the longer 13A" (4.4 cm) anti-tip bracket.
Locate a stud on the wall behind the range. Measure the
distance from top of rear brace to floor.
A
A. Rear brace
B. Top of rear brace to floor
C. Top of rear brace
D. Floor
3. Add SAd'(0.79 cm) to the measurement from Step 2. This will
allow anti-tip bracket to slide over rear brace.
4. Using the final measurement from Step 3, measure from the
floor up and mark a horizontal line on the wall where a wall
stud is located.
D_
I
I
I
(
(
(
(
(
(
I
A. Horizontal line marked from Step 4.
B. Wall stud
C. Mounting screws
D. Anti-tip bracket
5.
Position top of anti-tip bracket at line marked in Step 4 and
mark holes. Drill two 1/8"holes at the positions marked on the
wall. Use screws provided to fasten anti-tip bracket to wall.
Anti-tip bracket must be mounted securely to stud in wall
behind the range. Depending on thickness of the wall, longer
screws may be required. Longer screws are available from
your local hardware store.
al
Electrical Shock Hazard
Disconnect power before servicing.
Use 8 gauge solid copper wire.
Electrically ground range.
Failure to follow these instructions can result in death,
fire, or electrical shock.
This range must be connected to a grounded, metallic permanent
wiring system or a ground connector should be connected to the
ground terminal or wire lead on the range.
This range is manufactured
with a cabinet-connected,
green or
bare ground wire. Connect the range cable to the junction box
through the UL listed or CSA approved conduit connector.
Electrical
Connection
Options
If your home has:
And you will be
Go to Section:
connecting to:
4-wire direct
A fused
4-Wire Cable from
disconnect
or
Power Supply
circuit breaker
box
(12.7 crn)
3-wire direct
A fused
3-Wire Cable from
disconnect
or
Power Supply
circuit breaker
box