voltage from the socket of the
power supply can be output.
3. When connecting devices to
the generator, make sure to
connect these devices in
order. Connect the large
loads onto the generator first.
If everything is functional,
smaller loads can then be
added. If the generator shuts
off, it may be because the
load being drawn by all the
various devices are too high.
In this event, decrease the
number of small devices until
everything is functional. The
total drawn power should not
exceed the maximum output
power of the generator.
Please see Table 1-1 for
Table 2-1.
Note: Do not start more than two devices simultaneously. Each device should be
started one by one to prevent overloading the generator.
The generator should be running at 3600 revolutions per minute in order to achieve
the (60 Hz) frequency. The speed of the engine can be adjusted from the speed
governor.
2-7.3 Charging the battery
1. For the electric starter on the generator welder, the 12V battery is
automatically charged through the regulator on the side of the engine when it
is running.
2. If the generator is not used for long periods of time, the battery should be
disconnected to avoid energy loss from the battery.
3. Do not connect the negative and positive terminals of the battery together at
any time. Doing so will damage the battery and cause serious injuries.
4. Do not reverse the polarities when attaching the battery cables to the battery.
Doing so will damage both the battery and the electric starter.
5. When charging the battery, the battery produces flammable gases. Do not
smoke, let flames, and sparks get near the battery while it is charging as this
may cause a fire. To avoid sparking while connecting the cables to the
battery, first, connect the cables to the battery then to the motor. To
disconnect battery cables, first disconnect the motor end of the cable.
technical specifications of
what the generator can
output. In order to reset the
generator after overdrawn
power, let it sit for several
minutes. If the indication of
the voltmeter is too high or
too low, adjust the speed
accordingly. If there are
problems, stop the generator
immediately and fix the
issue.
4. During operation, the
generator should be in a place
that has very good
ventilation. Never cover the
engine to solve a ventilation
problem, as this will damage
your equipment.