Maintenance; Unscrew The Front Cover; Sight Glass - Worcester GREENSTORE Instruction Manual

6kw, 7kw, 9kw & 11kw combi heat pump
Hide thumbs Also See for WORCESTER GREENSTORE:
Table of Contents

Advertisement

Maintenance

The heat pump requires a minimum of maintenance, however, it is recom-
mended that the heat pump is checked annually by a qualifi ed installer.

Sight glass

Expansion vessel
Particle fi lter

Unscrew the front cover

Open the front cover to access some of the maintenance areas, e.g. the
sight glass and fi lter. The front cover is secured at the top by two screws.
To remove the front cover from the heat pump:
1. Unscrew the two screws on the top. (See picture)
2. Tilt the front cover forwards.
3. Lift the front cover up to release the lower edge.
Sight glass
Bubbles may be seen for several minutes during the initial start up of the
appliance. If bubbles are there continuously during operation, contact the
customer service department.
Sight glass
If the sight glass shows green this means there is no moisture in the
system. If it is yellow, there is moisture in the system. If this happens,
contact the customer service department.
The main power supply must be
disconnected before working on the
heat pump.
Only an accredited refrigeration
company is permitted to work on the
refrigerant circuit.
33
Warning
Remove the front cover by
unscrewing the screws on the top.
Maintenance

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Greenstore 6Greenstore 7Greenstore 9Greenstore 11

Table of Contents