Camera signal - Protect the cable with a primary protector if the camera sig-
nal is beyond 140 feet, in accordance with NEC 800 (CEC Section 60).
Coax grounding
U.S.A. models only - Section 810 of the National Electrical Code, ANSI/NFPA
No.70, provides information regarding proper grounding of the mount and
supporting structure, grounding of the coax to a discharge unit, size of
grounding conductors, location of discharge unit, connection to grounding
electrodes, and requirements for the grounding electrode.
Disposal - Your Bosch product was developed and manufac-
tured with high-quality material and components that can be
recycled and reused. This symbol means that electronic and
electrical appliances, which have reached the end of their work-
ing life, must be collected and disposed of separately from
household waste material. Separate collecting systems are usu-
ally in place for disused electronic and electrical products.
Please dispose of these units at an environmentally compatible
recycling facility, per European Directive 2002/96/EC.
Environmental statement - Bosch has a strong commitment towards the
environment. This unit has been designed to respect the environment as
much as possible.
Electrostatic-sensitive device - Use proper CMOS/MOS-FET handling precau-
tions to avoid electrostatic discharge. NOTE: Wear required grounded wrist
straps and observe proper ESD safety precautions when handling the elec-
trostatic-sensitive printed circuit boards.
Outdoor signals - The installation for outdoor signals, especially regarding
clearance from power and lightning conductors and transient protection,
must be in accordance with NEC725 and NEC800 (CEC Rule 16-224 and CEC
Section 60).
Permanently connected equipment - Incorporate a readily accessible discon-
nect device in the building installation wiring.
Pluggable equipment - Install the socket outlet near the equipment so it is
easily accessible.
docnumber | V 2.0 | 2007.01
Ground the cable system if connecting an outside cable
system to the unit.
Connect outdoor equipment to the unit's inputs only after
this unit has had its grounding plug connected to a
grounded outlet or its ground terminal is properly con-
nected to a ground source.
Disconnect the unit's input connectors from outdoor
equipment before disconnecting the grounding plug or
grounding terminal.
Follow proper safety precautions such as grounding for
any outdoor device connected to this unit.