KitchenAid KGRS308BSS1 Installation Instructions Manual page 8

30" (76.2 cm) freestanding gas ranges
Table of Contents

Advertisement

Available languages

Available languages

1,
2.
3=
f"sskx A'
B xc<®'t
Tip Over Hazard
A child or adult can tip the range and be killed.
Install anti-tip bracket to floor or wall per installation
instructions.
Slide range back so rear range foot is engaged in the
slot of the anti-tip bracket.
Re-engage anti-tip bracket if range is moved.
Do not operate range without anti-tip bracket installed
and engaged.
Failure to follow these instructions can result in death
or serious burns to children and adults.
Remove the anti-tip bracket from where it is taped inside the
storage drawer, warming drawer, or premium storage drawer.
Determine which mounting method to use: floor or wall.
If you have a stone or masonry floor, you can use the wall
mounting method. If you are installing the range in a mobile
home, you must secure the range to the floor.
Determine and mark centerline of the cutout space. The
mounting can be installed on either the left side or right side
of the cutout. Position mounting bracket against the wall in
the cutout so that the V-notch of the bracket is
129/le'' (31.9 cm) from centerline as shown.
Centerline
i
i
/
/
/
/
/
4,
illustrations.
Floor Mounting
Rear position
A. 12_/'
(31.9 cm)
B. Bracket V-notch
Drill two 1/8"(3 mm) holes that correspond to the bracket
holes of the determined mounting method. See the following
Front position
Diagonal (2 options)
8
Wall Mounting
5. Using the Phillips screwdriver, mount anti-tip bracket to the
wall or floor with the two #12 x 1s/8 '' screws provided.
6. Move range close enough to opening to allow for final gas
and electrical connections.
Remove shipping base,
cardboard or hardboard from under range.
7. Move range into its final location, making sure rear leveling
leg slides into anti-tip bracket.
8=
Move range forward onto shipping base, cardboard or
hardboard to continue installing the range using the following
installation instructions.
Explosion Hazard
Use a new CSA International approved
gas supply
line.
install
a shut=off valve.
Securely
tighten
all gas connections.
if connected to LP, have a qualified
person make sure
gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified
person include:
licensed heating
personnel,
authorized
gas company personnel, and
authorized
service
personnel.
Failure to do so can result in death, explosion,
or fire.
Typical rigid pipe connection
A combination
of pipe fittings must be used to connect the range
to the existing gas line. Your connections
may be different,
according to the supply line type, size and location.
1. Apply pipe-joint compound
made for use with LP gas to all
pipe thread connections.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents