Gas supply
requirements
Explosion
Hazard
Use a new A.G.A./C.G.A.
approved
gas
supply
line.
install a shutoff
valve.
Securemy tighten
all gas connections.
if connected
to L.P. have a qualified
person
make sure gas pressure
does not exceed
14 '° water column.
Examples
of a qualified
person
include
licensed heating personnel,
authorized
gas
company
personnel,
and authorized
service
personnel.
Failure to do so can result in death,
explosion,
or fire.
Observe all governing
codes and ordinances.
important:
Range must be connected
to a
regulated
gas supply.
This installation must conform with local
codes and ordinances. In the absence of
local codes, installations must conform
with American National Standard, National Fuel
Gas Code ANSI Z223.1 --latest
edition* or
CAN/CGA=B149 --latest
edition** installation
codes.
Input ratings shown on the modeVseriaJ
rating plate are for elevations up to 2,000
feet (609.6 m). For elevations above
2,000 feet (609.6 m), ratings are reduced at a rate
of 4% for each 1,000 feet (304.8 m) above sea
level. (Not applicable for Canada.)
This range is equipped for use with
Natural gas. It is design=certified by
A.G.A./C.G.A. for Natural and LR gas
with appropriate conversion. The model/serial
rating plate, located on the oven frame behind the
drawer, has information on the type of gas that can
be used. If this information does not agree with the
type of gas available, check with your KitchenAid
dealer.
Provide a gas supply line of 3/4" (1.9 cm)
rigid pipe to the range location. A smaller
size pipe on long runs may result in
insufficient gas supply. Pipe-joint compounds
appropriate for use with L.R gas must be used.
With L.R gas, piping or tubing size can be 1/2"
(1.3 cm) minimum. L.R gas suppliers usually
determine the size and materials used on the
system.
Copies of the standards listed may be obtained from:
* American
Gas Association
151 $ WHson Boulevard
Arlington,
Virginia
22209
* * Canadian
Standard
Association
178 Rexdale Boulevard
Btobicoke,
(Toronto),
Ontario
Mgw 1R3
lf local codes permit, a new
A.G.A./C.G.A. design-certified,
4-5 foot
(122 -152.4 cm) long, 1/2" (1.3 cm) or
3/4" (1.9 cm) I.D., flexible metal appliance
connector is recommended
for connecting this
range to the gas supply line. Do Not kink or
damage the flexible tubing when moving the range.
A 1/2" (1.3 cm) male pipe thread is needed for
connection to pressure regulator female pipe
threads.
shutoff
va}ve
"open"
poeiti__
to range
?_
pply
The supply line shall be equipped with an
approved shutoff valve. This valve should
be located in the same room, but external
to the range, and should be in a location that
allows ease of opening and closing. Do Not block
access to shutoff valve.
,rgdppo
s glssup
line, a combination of pipe fittings
must be used to obtain an in=line
connection to the range. All strains must be
removed from the supply and fuel lines so range
will be level and in line.
The regulator setting must be checked at
a minimum of 1 inch water column above
the manifold pressure. The inlet pressure
to the regulator should be as follows for operation:
Natural gas:
Manifold
pressure -- 5 inches
Maximum
pressure
-- 14 inches
L.P. gas:
Manifold
pressure-
10 inches
Maximum
pressure
-- 14 inches
Line pressure
testing:
Testing above 112 psi (gauge)
The range and its individual shutoff vahie
must be disconnected from the gas supply piping
system during any pressure testing of that system
at test pressures greater than 1/2 psig (3.5 kPa).
Testing at 1f2 psi (gauge) or lower
The range must be isolated from the gas supply
piping system by closing its individual manual
shutoff valve during any pressure testing of the gas
supply piping system at test pressures equal to or
less than 1/2 psig (3.5 kPa).
requ
Electrical Shock Hazard
Plug into a grounded 3-prong outlet.
Do not remove ground prong.
Do not use an adapter.
Failure to follow these instructions can result
in death, fire, or electrical shock.
If codes permit and a separate
ground wire is
used, it is recommended
that a qualified
electrician determine that the ground path is
adequate.
Check with a qualified electrician if you are not
sure whether the range is properly grounded.
Do Not ground to a gas pipe.
A 120=volt, 60=Hz, AC=only, 15=ampere, fused
electrical circuit is required. A time=delay fuse or
circuit breaker is recommended. It is recommended
that a separate circuit serving only this range be
provided.
Electronic ignition systems operate within wide
voltage limits, but proper ground and polarity are
necessary. In addition to checking that the outlet
provides 120=volt power and is correctly grounded,
the outlet must be checked by a qualified
electrician to see if it is wired with correct polarity.
The wiring diagram is included in the literature
package. The wiring diagram can also be found on
the back of the range.
Note: The metal chassis of the range MUST be
grounded in order for the control panel to work. If
the metal chassis of the range is not grounded, NO
keypads will operate. Check with a qualified
electrician if you are in doubt as to whether the
metal chassis of range is grounded.
Recommended
ground
method
For personal safety, this range is equipped with a
power supply cord having a 3=prong ground plug.
To minimize possible shock hazard, the cord must
be plugged into a mating 3=prong, ground=type
outlet, grounded in accordance with the National
Electrical Code, ANSI/NFPA 70 -- latest edition*
or CSA Standard C22.1, Canadian Electrical Code,
Part 1, -- latest edition** and all local codes and
ordinances. If a mating outlet is not available, it is
the personal responsibility and obligation of the
customer to have a properly grounded, 3=prong
outlet installed by a qualified electrician.
WARNING = improper connection of the
equipment=grounding
conductor can result in a risk
of electric shock. Check with a qualified electrician
or servicemen if you are in doubt as to whether the
appliance is properly grounded. Do not modify the
plug provided with the appliance = if it will not fit the
outlet, have a proper outlet installed by a qualified
electrician.
power
supply
cord.
3=prong
"_
ground=type
outlet
ground
plug
ground
prong
O
Panel C