Download Print this page

KitchenAid KERS505XSS00 Installation Instructions Manual page 8

Freestanding electric range with double ovens

Advertisement

Available languages

Available languages

Power Supply Cord
Electrical Shock Hazard
Disconnect power before servicing.
Use a new 40 amp power supply cord.
Plug into a grounded outlet.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Direct Wire
Electrical
Shock Hazard
Disconnect
power before servicing.
Use 8 gauge copper
or 6 gauge aluminum
wire.
Electrically
ground
range.
Failure to follow these instructions can result in death,
fire, or electrical
shock.
1=
2.
3.
Disconnect
power.
Use Phillips screwdriver to remove the terminal block cover
screw located on the back of the range. Pull cover down and
toward you to remove cover.
Remove plastic tag holding three 10-32 hex nuts from the
middle post of the terminal block.
4=
Add strain relief.
Style 1: Power supply cord strain relief
Assemble a UL listed strain relief in the opening.
A
A. UL listed strain relief
Feed the power supply cord through the strain relief in the
cord/conduit
plate on bottom of range. Allow enough
slack to easily attach the wiring to the terminal block.
Tighten strain relief screw against the power supply cord.
8

Advertisement

loading