Test Run - Mitsubishi Electric Mr. SLim SEZ-KD09NA Installation Manual

Air conditioners
Hide thumbs Also See for Mr. SLim SEZ-KD09NA:
Table of Contents

Advertisement

Available languages

Available languages

8. Electrical
work
Function table 1
Select unit number 00
Mode
Power failure automatic recovery*l
(AUTO RESTART FUNCTION)
Indoor temperature
detecting
LOSSNAY connectivity
Settings
Mode no.
Not available
01
Available
"1
Indoor unit operating average
Set by indoor unit's remote controller
02
Remote controller's
internal sensor
Not Supported
Supported
(indoor unit is not equipped with outdoor-air
intake)
03
Supported
(indoor unit is equipped
with outdoor-air
intake)
Setting no.
Initial setting
1
2
O
1
O
2
3
1
O
2
3
Check
Function
table 2
Select unit numbers 01 to 04 or all units (AL [wired remote controller]/07
[wireless remote controller])
Mode
Settings
Filter sign
100 Hr
2500 Hr
No filter sign indicator
External static pressure
15 Pa (0.06 in.WG)
35 Pa (0.14 in.WG)
50 Pa (0.20 in.WG)
The same as setting of mode no.08
5 Pa (0.02 in.WG) (set mode no. 08 to 1 )
Mode no.
Setting no.
Initial setting
1
O7
2
3
O
1
O
08
2
3
1
O
10
2
"1 When the power supply returns, the air conditioner will start 3 minutes later.
Note: When the function of an indoor unit were changed by function selection
after the end of installation,
always indicate the contents by
appropriate
check filed of the tables.
Check
entering a O or other mark in the
9. Test run
9.1. Before test run
After completing installation and the wiring and piping of the indoor and outdoor
units, check for refrigerant leakage, looseness in the power supply or control
wiring, wrong polarity, and no disconnection
of one phase in the supply.
Use a 5OO-volt megohmmeter
to check that the resistance
between the power
supply terminals
and ground is at least 1.0 M_.
Do not carry out this test on the control wiring (low voltage circuit) termi-
nals.
//_ Warning:
Do not use the air conditioner
if the insulation resistance
is less than 1.0 MQ.
Insulation
resistance
After installation
or after the power source to the unit has been cut for an extended
period, the insulation
resistance will drop below 1 M_Qdue to refrigerant
accumulat-
ing in the compressor.This
is not a malfunction.
Perform the following procedures.
1. Remove the wires from the compressor
and measure the insulation resistance
of
the compressor.
2. If the insulation resistance
is below 1 M£_, the compressor
is faulty or the resist-
ance dropped due the accumulation
of refrigerant
in the compressor.
3. After connecting the wires to the compressor,
the compressor
will start to warm
up after power is supplied. After supplying
power for the times indicated
below,
measure the insulation resistance
again.
• The insulation resistance
drops due to accumulation
of refrigerant
in the com-
pressor. The resistance
will rise above 1 M_Q after the compressor
is warmed
up for two to three hours.
(The time necessary
to warm up the compressor
varies according
to atmos-
pheric conditions and refrigerant
accumulation.)
• To operate the compressor
with refrigerant
accumulated
in the compressor,
the compressor
must be warmed up at least 12 hours to prevent breakdown.
4. If the insulation
resistance
rises above 1 M_Q,the compressor
is not faulty.
Z_ Caution:
• The compressor
will not operate unless the power supply phase connection
is correct.
• Turn on the power at least 12 hours before starting operation.
- Starting operation immediately
after turning on the main power switch can result in
severe damage
to internal parts. Keep the power switch turned on during the op-
erational season.
9.2. Test run
9.2.1.
Using
wired
remote
controller
Q Turn on the power at least 12 hours before the test run.
@ Press the [TEST] button twice. -_ "TEST RUN" liquid crystal display
Q
Press the [Mode selection]
button. -_ Make sure that wind is blown out.
(_ Press the [Mode selection]
button and switch to the cooling (or heating) mode.
-_ Make sure that cold (or warm) wind is blown out.
@ Press the [Fan speed] button. -_ Make sure that the wind speed is switched.
@ Check operation of the outdoor unit fan.
Q
Release test run by pressing the [ON/OFF] button. -_ Stop
Q
Register a telephone
number.
The telephone
number of the repair shop, sales office, etc., to contact if an error
occurs can be registered
in the remote controller. The telephone
number will be
displayed when an error occurs. For registration
procedures,
refer to the operation
manual for the indoor unit.
[Fig. 9-1] (P.7)
(_) ON/OFF button
C_Test run display
(© Indoor temperature liquid line temperature display
(_) ON/OFF lamp
(_, Powerdisplay
@_Error code display
Test run remaining time display
G(_ Set temperature button
(A_Mode selection button
(i_ Fan speed button
@ TEST button
14