Download Print this page

Whirlpool WED9150WW0 Installation Instructions Manual page 6

27" electric dryer
Hide thumbs Also See for WED9150WW0:

Advertisement

INSTALLATION
INSTRUCTIONS
Before you start: disconnect power.
2.
Attach power supply
cord strain
relief
Remove hold-down screw and terminal block cover.
INSTALL
STUN
RELIEF
If installing power supply cord strain relief, continue with
steps 2-3.
if installing direct wire strain relief, continue with steps 4-5.
Power
supply
cord
strain
relief:
Fire Hazard
Use a new UL listed 30 amp power supply cord.
Use a UL listed strain relief.
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center
terminal
(silver).
Ground wire (green or bare wire) must be connected to
green ground connector.
Connect remaining 2 supply wires to remaining
2 terminals
(gold).
Securely tighten
all electrical connections.
Failure to do so can result in death, fire, or
electrical shock.
Remove screws from 3/4" (19 mm) UL listed strain relief (UL
marking on strain relief). Put two clamp section tabs into hole
below terminal block opening with one tab pointing up and one
pointing down. Hold in place and tighten strain relief screws
enough to hold two clamp sections together.
Attach power supply
cord
to strain
relief
Put power supply cord through strain relief. Be sure that wire
insulation on power cord is inside strain relief. Strain relief should
be a tight fit with dryer cabinet and be in a horizontal position.
Do not tighten strain relief screws at this point. Now skip to
step 6.
6