ELECTRICAL
REQUIREMENTS
LOCATE THE POLARIZED OUTLET IN REAR WALL
ABOVE UNIT, VISIBLE THROUGH CABINET DOORS
ABOVE UNIT. (DISCONNECT
ELECTRIC
SUPPLY
BEFORE SERVICING).
A 120 Volt, 60 Hz, AC only, 15 or 20 Ampere fused elec-
trical supply is required
(time delay fuse or circuit
breaker is recommended).
It is recommended
that a
separate circuit servicing only this appliance
be pro-
vided. DO NOT use an extension cord.
WARNING:
Improper connection of the equipment
grounding
conductor can result in a
risk of electrical shock.
RECOMMENDED
GROUNDING
METHOD
DO NOT, UNDER ANY CIRCUMSTANCES,
REMOVE
THE POWER SUPPLY CORD GROUND PRONG.
For your personal
safety,
this appliance
must be
grounded.
This appliance
is equipped with a power
supply cord having
a 3-prong grounding
plug. To
minimize possible shock hazard it must be plugged in-
to a mating 3-prong grounding type wall receptacle,
grounded in accordance with a National Electrical Code
and local codes and ordinances. If a mating wall recep-
tacle is not available, it is the personal responsibility
and obligation
of the customer
to have a properly
grounded
3-prong
wall
receptacle
installed
by a
qualified electrician. See Figure 2.
SINGLE 3-PRONG
GROUNDING
TYPE WALL RECEPTACLE
3-PRONG
Figure 2
VENTILATION
IMPORTANT: WALL AND ROOF CAPS MUST HAVE
BACKDRAFT
DAMPER.
NOTE: Ductwork, wall and roof caps not supplied with
hood.
Select venting prior to installation. This oven must be
vented one of three ways:
A. Outside
Venting
through the top surface
of
the unit.
B. Outside
Venting
through
the
rear
surface
of the unit.
C. Inside Venting of this oven requires Whirlpool recir-
culating filter kit #RCH6000, Part #788000. Contact
your Whirlpool Dealer to obtain this kit before pro-
ceeding. Separate instructions are included in the
recirculating filter kit.
Exhaust
Connection
The exhaust duct connects to a standard 31/4 '' x 10"
rectangular duct.
If existing duct is round, a rectangular-to-round
adap-
tor must be used. In addition, install a rectangular
3" extension duct between
the damper
assembly
and adaptor
to prevent
sticking of the exhaust
damper.
RECTANGULAR-TO-ROUND
ADAPTOR__
CAUTION: If the rear exhaust option is selected be sure
that there is proper clearance within the wall for the ex-
haust duct.
IMPORTANT:
THE VENTING SYSTEM MUST TER-
MINATE TO THE OUTSIDE.
DO NOT TERMINATE
THE VENT IN AN ATTIC OR OTHER ENCLOSED
SPACE. THIS MAY RESULT IN A FIRE HAZARD.
TO INSURE
PROPER
AIR
MOVEMENT
AND
VELOCITY:
Attic Venting: Never vent to either attic or crawl space.
Unit must always be ducted to the outside.
Uniform Size: All ducting should be uniform throughout
the complete system for proper performance.
Duct Restrictions: Never install two elbow fittings next
to each other. This causes unusual air patterns and
subsequently interrupts velocity and the end result is
poor ventilation.
Sealing Joints: All joints in the duct system must be
tightly taped to avoid smoke and odor in the home.
Also, be sure to caulk thoroughly all joints in floor or
wall where duct system goes to the outside.