Download Print this page

Tools Needed; Parts Supplied - Whirlpool RS610PXGV7 Installation Instructions

30" drop-in electric range

Advertisement

28-3/16"
cooktop
recessed width
__
28-5/32"
oven
recessed
width
24-13/32"
to back
30-3/4"
recessed
height
from
underside
of cooktop
to support
slats
31-1/2"
overall
cooktop
width
shipping
foot
23-1/8"
recessed_
depth
"_
30"
overall
width
31-11/16"
overall
height
r
J
Countertop
preparation:
Front edges: You may need to
shave or cut the trim of formed
or metal front-edged
countertops to clear the 30"
width of cooktop.
If countertop thickness is
more than 1-1/2" inches
thick: Countertop must be
notched as shown to avoid
damaging the oven control
panel.
notch
width
_
_._
to be equal
/_J_j
_'_
I--1-1/2"
_
_'_
_
max
30-1/8"
If countertop extends more
1-1/8" beyond cabinet front:
Notch countertop as shown
to clear oven control panel.
notch width
to be equal
both sides
cabinet
front
wall
floor
\
13" max. upper
t
For minimum
clearances
to the
top
of cooktop
see
Note.*
--r
- 19-5/8"
-_
25" countertop
depth
24" lower
cabinet depth
r
Side view of
cabinet cutout
_1_1-1/8"
max.
X
cabinet
front
*Note: 24" min. when bottom of wood
or
metal cabinet is protected by not less than
1/4" flame retardant
millboard
covered
with not less than No. 28 MSG sheet steel,
0.015" stainless steel, 0.024" aluminum
or
0.020" copper,
30" rain. clearance between
the top of the
cooking platform and the bottom of an
unprotected
wood or metal cabinet.
Page 1
Copies of the standards listed may be obtained from:
** National Fire Protection Association
Batter/march Park
Quincy, Massachusetts 02269
1-1/2" max.
thickness
Top view of
cabinet cutout
1/4"
radius both
corners
30-3/4"
top of
countertop
to
support slats
Install a 3-1/2"-wide
support slat on each
side, Slats must be level
front to back and with
each other.
Top of countertop
_28-1/2"
min.
Note:
countertop
I
opening
width
must
be level
/
28-5/8"
across
front
and
/
_
is
front
to back.
I
recommended.
_/
if available.
Locate electrical
supply junction
box on cutout
floor or on rear
wall (shown)
near floor line.
7/8" min.
required
between
cutout
and
cabinet door
or hinge.
13
Front view of
cabinet cutout
==+t
30-3/4"
top of
36" overall
counter-
countertop
top to
height
bottom
of cabinet _
cutout
Your safety and the safety of others is very
important.
We have provided many important safety messages in this
manual and on your appliance. Always read and obey all
safety messages.
_J
his is the safety aiert symbol
This symboi alerts you to hazards that can kili or
hurt you and others. Aii safety messageswili be
preceded by the safety aiert symboi and the word "DANGER"
or "WARNING"=These words mean:
You wiJ be killed or
seriously injured if you
don't follow instructions.
You caj be killed or
seriously injured if you
don't follow instructions.
All safety messages will identify the hazard,tell you how to
reduce the chance of injury, and tell you what can happen if
the instructions are not followed.
Important: Observe all governing codes and
ordinances.
Proper installation is your responsibility. Have a qualified
technician install this range.
Range location should be away from strong draft areas,
such as windows, doors and strong heating vents.
Cabinet opening dimensions that are shown must be used.
Given dimensions provide minimum clearance.
Recessed installation area must provide complete
enclosure around the recessed portion of the range.
Electrical ground is required. See "Electrical requirements."
IMPORTANT: Some cabinet and building materials are not
designed to withstand the heat produced by the oven for
baking and self-cleaning. Check with your builder or cabinet
supplier to make sure that the materials used will not
discolor, delaminate or sustain other damage.
Range support surface MUST be solid, level and flush with
bottom of cabinet cutout.
Do not seal range to side cabinets.
When installing a cooktop under existing cabinets and the
installation does not meet the minimum cabinet clearances.
Install a range hood above the cooktop to avoid burn
hazards.
It is the customer's responsibility:
To contact a qualified electrical installer.
To assure that the electrical installation is adequate and in
conformance with National Electrical Code, ANSI/NFPA
70 -- latest edition**, and all local codes and ordinances.
Mobile home installation
The installation of this range must conform to the
Manufactured Home Construction and Safety Standards,
l]tle 24 CFR, Part 3280 (formerly the Federal Standard for
Mobile Home Construction and Safety, l]tle 24, HUD, Part
280); or when such standard is not applicable, the Standard
for Manufactured Homes Installations (Manufactured Home
Sites, Communities and Setups), ANSI A225.1/NFPA 501A,
or with local codes.**
When this range is installed in mobile home, it must be
secured to the floor during transit. Any method of securing
the range is adequate as long as it conforms to the
standards listed above.
Four-wire power supply cable must be used in a mobile
home installation. The appliance wiring will need to be
revised. See four-wire electrical connection, Page 3.
Tools needed:
2" alia,
uter bit
s
river
Parts supplied:
screws
2 door removal
pins

Advertisement

loading

This manual is also suitable for:

Rs610pxgw0Rs610pxgw2Rs610pxgv3Rs610pxgv2Rs610pxgw3Rs610pxgw7 ... Show all