Installation Requirements; Electrical Requirements; Tools And Parts - Whirlpool GGE350LWS00 Installation Instructions Manual

Freestanding electric range with double ovens
Table of Contents

Advertisement

INSTALLATION REQUIREMENTS
Gather the required tools and parts before starting installation.
Read and follow the instructions
provided with any tools listed
here.
Tools needed
Tape measure
Wrench or pliers
Level
3/8"nut driver
Phillips screwdriver
Hand or electric drill
Flat-blade screwdriver
1/8"(3.2 mm) drill bit
Parts supplied
Check that all parts are included.
3 - 10-32 hex nuts (attached to terminal block)
3 - Terminal lugs
Oven racks
2 - #12 x 18/8 '' screws (for mounting anti-tip bracket)
Anti-tip bracket (taped inside upper oven with literature
package)
Anti-tip bracket must be securely mounted to back wall or
floor. Thickness of floor may require longer screws to anchor
bracket to subfloor. Longer screws are available from your
local hardware store.
Parts needed
If using a power supply cord:
A UL listed power supply cord kit marked for use with ranges.
The cord should be rated at 250 volts minimum, 40 amps or
50 amps that is marked for use with nominal 13/8"(3.5 cm)
diameter connection opening and must end in ring terminals
or open-end spade terminals with upturned ends.
A UL listed strain relief.
Check local codes. Check existing electrical supply. See
"Electrical Requirements" section.
It is recommended
that all electrical connections be made by a
licensed, qualified electrical installer.
IMPORTANT: Observe all governing codes and ordinances.
It is the installer's responsibility to comply with installation
clearances specified on the model/serial number rating label.
The model/serial number rating label is located on the bottom
right front of the toe kick plate.
The range should be located for convenient use in the kitchen.
To eliminate the risk of burns or fire by reaching over heated
surface units, cabinet storage space located above the
surface units should be avoided. If cabinet storage is to be
provided, the risk can be reduced by installing a range hood
that projects horizontally a minimum of 5" (12.7 cm) beyond
the bottom of the cabinets.
Cabinet opening dimensions that are shown must be used.
Given dimensions are minimum clearances.
The floor anti-tip bracket must be installed. To install the anti-
tip bracket shipped with the range, see "Install Anti-Tip
Bracket" section.
Grounded electrical supply is required. See "Electrical
Requirements" section.
IMPORTANT: To avoid damage to your cabinets, check with your
builder or cabinet supplier to make sure that the materials used
will not discolor, delaminate or sustain other damage. This range
has been designed in accordance with the requirements of UL
and CSA International and complies with the maximum allowable
wood cabinet temperatures
of 194°F (90°C).
Mobile Home - Additional
Installation
Requirements
The installation of this range must conform to the Manufactured
Home Construction
and Safety Standard, Title 24 CFR, Part 3280
(formerly the Federal Standard for Mobile Home Construction
and
Safety, Title 24, HUD Part 280). When such standard is not
applicable, the Standard for Manufactured
Home Installations,
ANSI A225.1/NFPA 501A or with local codes.
Mobile home installations require:
When this range is installed in a mobile home, it must be
secured to the floor during transit. Any method of securing the
range is adequate as long as it conforms to the standards
listed above.
Four-wire power supply cord or cable must be used in a
mobile home installation. The appliance wiring will need to be
revised. See "Electrical Connection"
section.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gge350lwq00Gge350lwb00

Table of Contents