CLEANING YOUR ALARM:

brush to vacuum around the openings on the alarm. The outside of the alarm may be
wiped with a damp cloth.
AFTER CLEANING, CONFIRM THAT THE GREEN POWER LED BLINKS ONCE PER
MINUTE, AND TEST YOUR ALARM BY OPERATING THE TEST/RESET BUTTON.
DO NOT PAINT YOUR ALARM: The paint will block the vents and affect the alarm
function.
DO NOT SPRAY AIR REFRESHER, HOUSEHOLD CLEANER, OR INSECT KILLER
ON OR NEAR YOUR ALARM:
sensor and cause improper operation. The dwelling must be well ventilated when using
household cleaning supplies or similar contaminants.

8. WHAT TO DO WHEN THE ALARM SOUNDS

!
WARNING
Actuation of this device indicates the presence of carbon monoxide (CO) which
can KILL YOU.
If alarm signal sounds:
1) Operate reset/silence button;
2) Call your emergency services (tel. no. _______________________________)
[fire department or 911];
3) Immediately move to fresh air - outdoors or by an open door or window. Do
a head count to check that all persons are accounted for. Do not re-enter
the premises or move away from the open door/window until the emergency
services responders have arrived, the premises have been aired out, and
your alarm remains in its normal condition.
4) After following steps 1- 3, if your alarm reactivates within a 24 hour period,
repeat steps 1-3 and call a qualified appliance technician (tel. no.
________________________________) to investigate for sources of CO from
fuel burning equipment and appliances, and inspect for proper operation of
this equipment. If problems are identified during this inspection, have the
equipment serviced immediately.
inspected by the technician and consult the manufacturers' instructions, or
contact the manufacturers directly, for more information about CO safety
and this equipment. Make sure that motor vehicles are not, and have not
been, operating in an attached garage or adjacent to the residence.
MANUAL RESET: You can temporarily silence an audible alarm signal by pressing the
button. The red LED will flash 4 times, and the models 7035/7035SL will
TEST/RESET
display "OFF" for 5 seconds and then continue to display CO levels detected for 40 ppm
or more. If 70 ppm or more continues to be detected, the audible and visual alarm
signals will be automatically reactivated within 5 minutes. Do not wait to see if the alarm
is reactivated; follow above instructions immediately.
You can clean your alarm by using a vacuum cleaner
Certain kinds of aerosol chemicals will damage the
Note any combustion equipment not
- 9 -