Limitations Of Carbon Monoxide Alarms - Pro-Tech 7030SL Owner's Manual

9 volt battery co alarm, single station; 9 volt battery co alarm with lcd digital display and peak level memory, single station
Table of Contents

Advertisement

AUTOMATIC RESET: If a CO alarm activation is not manually reset, the horn will
sound for at least 5 minutes. After 5 minutes, the alarm will automatically reset itself
and return to normal operation if the CO which caused the alarm activation has cleared.
IF YOU HAVE BEEN AWAY FROM HOME and you return to find your alarm(s)
sounding, DO NOT ENTER YOUR HOME. Call the Fire Department from a
neighbor's home.
YOU HAVE BEEN ASSURED THAT IT IS SAFE TO DO SO.
Conditions which can result in transient CO situations:
1) Excessive spillage or reverse venting of fuel burning appliances caused by
outdoor ambient conditions, such as:
i)
Wind direction and/or velocity, including high gusts of wind. Heavy air in
the vent pipes (cold/humid air with extended periods between cycles).
ii) Negative pressure differential resulting from the use of exhaust fans.
iii) Simultaneous operation of several fuel burning appliances competing for
limited internal air.
iv) Vent pipe connections vibrating loose from clothes dryers, furnaces, or
water heaters.
v) Obstructions in or unconventional vent pipe designs which can amplify
the above situations.
vi) Poorly designed or maintained chimneys and/or vents.
2) Extended operation of unvented fuel burning devices (range, oven, fireplace, etc.).
3) Temperature inversions which can trap exhaust gases near the ground.
4) Car idling in an open or closed attached garage, or near a home.
If "service" (trouble) signal activates (chirps twice every minute, red LED blinks
for 5 seconds at same time), see Section 12 for service and return instructions.

9. LIMITATIONS OF CARBON MONOXIDE ALARMS

WARNING!
!
This product is intended for use in ordinary indoor locations
is not designed to measure compliance with Occupational Safety and Health
Administration (OSHA) commercial or industrial standards.
medical problems may consider using warning devices which provide audible
and visual signals for carbon monoxide concentrations under 30 ppm.
Carbon monoxide alarms respond to the presence of CO. They do not detect
smoke. If the alarm does activate, follow instructions in Section 8
THE ALARM SOUNDS
DO NOT RE-ENTER YOUR HOME FOR ANY REASON UNTIL
.
- 10 -
of family living units. It
Individuals with
WHAT TO DO WHEN