This appliance i sequipped witha copper c onductor
flexible cable. I f connection i smade to aluminum house
wiring,useonlyspecial connectors whichareapproved
forjoiningcopper a ndaluminum wiresin accordance
withthe National Electrical Codeandlocalcodes and
ordinances.
This appliance ismanufactured with aframeconnected
green (orbarecopper) g round wire.
.
If connecting
to a 3-wire
supply cable (U.S.A.
only):
If local codes permit connection
of the
frame grounding
conductor
to the neutral
(white)
wire: (The 3-conductor
cord or cable must be
replaced with a 4-conductor
cord or cable where
grounding through the neutral conductor is prohibited
in new installations, mobile homes, recreational
vehicles or in other areas where local codes do not
permit neutral grounding)
Connect the green (or bare copper) wire (and the
white wire for model with warmer zone) from the
appliance cable to the supply cable ground wire
(white or bare) inside the junction box. Connect the
remaining wires inside the junction box (see Figure 4
or 5) from the power supply cable to the matching
colors of the appliance cable wires.
Cable from Power Supply
Ground Wire
Red -
Wires
Black
Wires
Box
Ground Wire
::
U.L.-Listed Conduit
(Bare or Green Wire)
Connector (or CSA listed)
Cable from appliance
Figure 4 - U.S.A. Only
3-WIRE GROUNDED JUNCTION BOX
Ground
(Bare or
Cable from Power Supply
/
_
_
_Black
Ground
\,\Jr%[: .......... _.._'_J"_
-
Wires
Re)
_
}
Wire
'
, ....... J
_
U.L.-Listed Conduit
Green W re)
Connector (or CSA listed)
Cable from appliance
Figure 5 - U.S.A. Only
Models 36" with Warmer
Zone Only
3-WIRE GROUNDED JUNCTION BOX
_lmproper
connection
of aluminum
house wiring
to copper leads can result in a short
circuit or fire. Use only connectors
designed
for
joining
copper to aluminum,
and follow
the
manufacturer's
recommended
procedure
closely.
.
If connecting
to a 4-wire
supply cable (also
mobile
homes):
The appliance frame must not be
connected to the neutral wire of the 4-wire electrical
system. Connect the appliance white wire (if a 4-wire
appliance cable is supplied) to the power supply cable
white wire. Cap the white wire from the power
supply cable if a 3-wire appliance cable is supplied.
Connect the remaining wires from the supply cable to
the matching color wires from the appliance cable
(see Figure 6 or 7). The green (or bare copper) wire
must now be used to ground the appliance in
accordance with local electrical codes. The green (or
bare copper) wire from the power supply cable is
grounded inside the house service panel.
Cable from Power Supply
Ground Wire
White Wire
Red
.....
ires
on Box
Ground Wire
,:._,_J
"<_U.L.-Listed
Conduit
(Bare or GreenW re}
Connector (or CSA listed)
Cable from appliance
Figure 6 - 4-WIRE GROUNDED JUNCTION BOX
Cable from Power Supply
Ground ,,\!ire_
__
"_ .......... _ !&-¢_-_
_- White Wire
Red[I',,.
I
Ground ,,\/ire
] jf_,((%\//[
_:_
,,\!ires
(Bare or Green Wire_X{!__
/
]__
White Wire
Junction Box
_
U.L.-Listed Conduit
Connector (or CSA listed)
Cable from
appliance
Figure 7 - 4-WIRE GROUNDED JUNCTION BOX
Models 36" with Warmer
Zone Only
DO NOT ground
to a gas supply
pipe.
DO NOT connect to electrical
power
supply until
appliance
is permanently
grounded.
Connect the
ground
wire before turning
on the power.