Air Distribution Systems; Closet To Door Clearance - 5" Or Greater - Coleman DGAA Installation Manual

High efficiency sealed combustion gas furnace (single stage downflow only) 56-90 mbh input (16.41 -26.38 kw)input
Table of Contents

Advertisement

129098-UIM-H-1011
AWARNING
The supply air temperature
MUST NEVER exceed the Maximum
Supply
Air Temperature,
specified on the nameplate.
Operating the furnace above the maximum
supply air temperature
will cause the heat exchanger to overheat, causing premature heat
exchanger
failure. Improper
duct sizing, dirty air filters, incorrect
manifold pressure, incorrect gas orifice and/or a faulty limit switch
can cause the furnace to operate above the maximum supply air
temperature.
Refer to sections II, III and XI for additional informa-
tion on correcting the problem.
DUCTWGRK
INSTALLATION
Air Distribution
Systems
For proper air distribution, the supply duct system shall be designed so
that the static pressure does not exceed the listed static pressure rating
on the furnace rating plate.
Three typical distribution systems are illustrated in Figure 2.
Location, size and number of registers should be selected on the basis
of best air distribution and floor plan of the home.
The Air Temperature
Rise is to be adjusted to obtain a temperature
rise
within the range(s) specified on the furnace rating plate.
DUCT
DESIGN
- CANADA
Supply duct design shall be in accordance
with the latest HRA Digest,
the ASHRAE Handbook Fundamentals,
or other good engineering
prin-
ciples.
NOTE: Refer to HRA Digest Residential
Air System Design Manual,
Sections 5 and 6, the requirements
of which are summarized
as fol-
lows:
1.
The kilowatt output of each duct register shall not exceed 2.35 kW.
2.
The furnace output should not be more than 20% greater than the
calculated
heat loss of the home. If a larger furnace is used, the
duct system shall be capable of the increased air volumes neces-
sary to maintain a maximum air temperature
rise of 50° C as the
air passes over the furnace heat exchanger.
3.
At least one warm air supply outlet shall be provided in each room.
4.
When rooms are located adjacent
to the exterior walls, warm air
outlets shall be located so as to bathe at least one exterior wall
and, where practical, a window area with warm air, except for bath-
rooms or kitchens where this might not be practical.
5.
Where practical, outlets shall be provided near the exterior doors
of the home.
CLEARANCE
REQUIREMENTS
- CANADA
Supply air ducts from warm air furnaces having a specified
minimum
plenum clearance shall maintain this clearance from combustible
mate-
rial for at least the distance specified in CSA Standards C22.2 No. 23 or
B140.10 or CGA Standard CAN/CGA-2.3.
A
Single trunk duct
C
Transition Duct with Branches
B*
Transition
duct
Dual trunk duct with crossover
connector
U_
Branches U
I
I
_r
Dual trunk duct
_,
Crossover
I
J
'_'-3
1. Crossover Duct must be centered
directly under furnace.
2. Use 12" (30.5 cm) Diameter Round or insulated Flex-duct only.
3. Terminate Flex-duct
(opposite furnace) in the center of the trunk duct.
4. Flex-duct material must be pulled tight
No Loops or unnecessary
dips
Air Flow may be impeded.
FIGURE 2: Air Distribution Systems
Return Air Grille Part No.
7900-287P/A
* White
250 IN. 2 (161 cm 2)
MINIMUM
FREE AREA
/50
IN. _(322 cm _)
_ MINIMUM
J FREE AREA
Furnace
to Closet
Door Clearance
--
5 ranches (12.7 cm) or more
The closet door MUST have a minimum of 250 ranches2(1613 cm 2)
of free area in the upper half of the door.
If opening for return air is located in the floor or sidewalls
and
below the top of the furnace casing:
1. 6 inches (15.2 cm) minimum clearance
must be provided on side
where return is located, and
2. 6 inches (15.2 cm) minimum clearance must be maintained
from
the front of furnace.
250 IN. 2 (161 cm 2)
FREE AREA
_- 5 in (12.7 cm) or greater * Closet
_
_o
Door C, .......
,
,
Return Air Closet Door Part No.
DOOR
7900-7771/C* White
FIGURE 3: Closet To Door Clearance - 5" or Greater
Johnson Controls Unitary Products
5