TANK DRAINING

FACTORY BLOWOUT
1. Disconnect the power and water supply to brewer. Allow brewer to cool before proceeding.
2. Remove 2 screws that secure the top cover. Remove the cover. Place brewer next to a sink.
3. Connect the brewer to the power source.
4. Press hidden switch until display reads "BREW LOCKOUT". Press and release until display reads "SERVICE
TOOLS?" Select "YES"
5. Display will read "TEST OUTPUTS?" Select "NO"
6. Display will read "FACTORY BLOWOUT?" Select "YES"
7. Display will read "BlowOut BrewTank".
8. Tilt brewer back towards sink slightly during this procedure! FIG. 9-1
9. Carefully clamp hose "A". Select "START" FIG. 9-2
10. When brew tank blowout mode is finished, select "NEXT".
11. Carefully clamp the Hot Water hose "B". Select "START". FIG. 9-2
12. When tanks are empty, disconnect power to the brewer.
13. Replace the top cover and tighten screws.
DO NOT CUT HOSES OR USE EXSESSIVE FORCE WHEN CLAMPING.
B
A
FIG 9-1
FIG 9-2
HOT WATER COULD ESCAPE FROM SPRAYHEAD OR HOT WATER DISPENSE AREA IF HOSES
ARE NOT COMPLETELY CLAMPED SHUT.