Ⅵ、Door Station Setting Order - Cusam Coding Intercom User Manual

Table of Contents

Advertisement

Ⅵ、Door
Door
station
Door station
station setting
CODE
DIGIT CODE
ORDER
*000
XXXX
XXXX
**00
(4 passwords)
XXXX
**01
(4 new passwords)
**02
000X
**03
0XXX
**04
0XXX
**05
000X
**06
0XXX
**07
0XXX
**08
0XXX
**09
000X
**10
000X
**11
0XXX
0XXX(Serial
**12
number)
XXXX(password)
**13
XXXX XXXX
YXXX(module
**15
address)
**16
000X
**17
000X
**18
XXXX(room No.)
**19
setting
order
setting order
order
Significance
The manager operates the lock
Confirmating the manager
password
Revising the manager password
Revising the coding method
Revising the ringing time
Revising the Dialogue time
Revising the ring types
Revising the waiting time after
ringing
Revising the time of operating
lock
Revising the waiting time after
opening the door
demonstration type at standby
state
Controlling thecode tube to
demonstrate or to slake when
picking up phone
revising the alarm time
Manager revising the unlock
password of users
establishing eight public
password to open locks
edits comparative table of "
onmipotent coding "
choosing the " dialing digit"
Which digit to demonstrate a
letter
Checking the room number of
onmipotent coding
Restoring factory setting
17
www.cusamintercom.com
remark
It should be confirm the manager password first
before using the order from **00 to **19
(Tacitly approves No, is 2098)
the efficient number are 1.2.3.6.7.8.9.0
"0" is the onmipotent coding (Tacitly approves
No, is 2)
001-255seconds(Tacitly approves No, is 60)
001-255seconds(Tacitly approves No, is 120)
0-9(0 is the "dingdong" sound, and 1-9 is the
phone sound) (Tacitly approves No, is 0)
001-255seconds(the user also can answer the
phone after the ring stopped) (Tacitly approves
No, is 1)
001-255seconds(unit is 0.2 second, tacitly
approves No, is 5,namely the time of unlocking
is 1 second)
001-255seconds(the talking time after opening
the door) (Tacitly approves No, is 20)
0-9 (Tacitly approves No, is 1)(0-off,1-9 are
demostrating)
0-1(Tacitly approves No, is 1)
0 is to slake
1 is to demonstrate
000-255seconds,000-close the alarm function.
(Tacitly approves No, is 000)
The scope of Serial number:000-239
password cancelling:0000
password cancelling:0000
Reference the comparative table of " onmipotent
coding "
Only suit for the onmipotent coding the
effective number is 1.2.3.4,(Tacitly approves No,
is 3)
The effective digit is 1-4,or the tacitly approves
demonstrate no letter
Checking the module address of the room
number in table "onmipotent coding"
Restoring the digits **02-**11,**16-**17 are
the factory tacitly approves No,