Page 1
www.cusamintercom.com VIDEO INTERCOM VIDEO VIDEO INTERCOM INTERCOM SYSTEM SYSTEM SYSTEM FOR APARTMENT APARTMENT APARTMENT (NETWORK) (NETWORK) (NETWORK) USER USER’ ’ ’ S S S MAUAL MAUAL USER MAUAL QUZHOU ZHUOCHENG ELECTRONIC CO.,LTD QUZHOU QUZHOU ZHUOCHENG ZHUOCHENG ELECTRONIC ELECTRONIC CO.,LTD CO.,LTD...
www.cusamintercom.com Contents Contents Contents (Install Using Instruction) (Install (Install and and Using Using Instruction) Instruction) 1.Function Introduction-------------------------------------------------------------------------3 2.Using Method-----------------------------------------------------------------------------------3 3.System Schematic and Wiring Diagram----------------------------------------------4-5 (1) System structure schematic drawing------------------------------------------------4 (2) system wiring diagram------------------------------------------------------------------5 4.Code Setting-------------------------------------------------------------------- -------------6-7 5.Table3.1 comparative table of initializating the first building door station number and Network switcher address-----------------------------------------------8-9 6.Table3.2 comparative table of initializating room number and extension phone address(the 1...
www.cusamintercom.com 1.Function 1.Function 1.Function Introduction Introduction Introduction ◇Function Function Function of of of managing managing center managing center center: Call any indoor phone and be called by any indoor phone; Be called by door station and overlook photo of door station; Time show in digital screen ◇Function Function...
Page 5
www.cusamintercom.com 3.System schematic and W W W iring iring diagram 3.System 3.System schematic schematic and iring diagram diagram ( ( ( 1 1 1 ) ) ) System System System structure structure structure schematic schematic schematic drawing drawing drawing...
www.cusamintercom.com 4 4 4 . . . Code Code setting Code setting setting Managing center---Door station number (Building number) Managing Managing center---Door center---Door station station number number (Building (Building number) number) setting setting setting There is a comparative table of door station number and Network switcher. Input”**15”to enter into this table,as follow steps:...
www.cusamintercom.com Comparative table table of of of Network Network Door Station number Comparative Comparative table Network Door Door Station Station number number and and the first address first first address address Door Station 001… … … 032 033… … … 064 065…...
www.cusamintercom.com 5.Table3.1 5.Table3.1 5.Table3.1 comparative comparative comparative table table table of of of initializ initializ initializat at ating ing the the first first first building building building door station number Network switcher address door door station station number number and and Network Network switcher switcher address...
www.cusamintercom.com Quick setting Quick Quick setting setting If code of room number corresponds with the rule of table 3.2 , the managing center provides a quick setting order“**41”.Do as follows:**00 XXXX ( Manager password,the original one is 2098 ) **41 , It will come to the programming rule of table3.2.
www.cusamintercom.com 7 7 7 、Table3.3 Table3.3 comparative table table of of of initializating initializating room number Table3.3 comparative comparative table initializating room room number number and extension phone address(the address(the 2 2 2 kind) extension extension phone phone address(the kind) kind) Module Module...
Page 12
www.cusamintercom.com 9 9 9 、Indoor Indoor phone setting Indoor phone phone setting setting (1)**00 XXXX(Manager Password,the original is 2098) ; (2)**15 and come up with Y011(Y stands for address,the 2 and 3 figure is the coding site) , input three figure stand for module address,the 4 figures to change the current address,Press“#”if you don’t want to change。...
Page 13
www.cusamintercom.com If the module address you want is 01:the block of short-circuit should be inserted in 1 place. If the module address you want is 03:the block of short-circuit should be interted in 1,2 place. If the module address you want is 07:the block of short-circuit should be inserted in 1,2,4 place If the module address you want is 19:the block of short-circuit should be inserted in 1,2,16 place...
Page 14
www.cusamintercom.com 11.Door station setting order 11.Door 11.Door station station setting setting order order Code order Digit code Significance Memo The manager unlock the *000 XXXX gate Confirm manager password before XXXX Confirmating the manager **00 using order from *00 to **21 (Original is (4 password) password 2098)
www.cusamintercom.com 000 - 255 seconds , 000-close the alarm **11 0XXX Revising alarm time function(Tacitly approves No. is000) 0XXX(serial No.) Manager revising The scope of serial number:000-239 **12 XXXX (password) unlock password of users Password 0000 is to cancel Establishing eight public **13 XXXX XXXX Password 0000 is to cancel...
www.cusamintercom.com 1 1 1 3 3 3 .Wrong .Wrong code form .Wrong code code form form Wrong code Significance Wrong code Significance Wrong Wrong code code Significance Significance Wrong Wrong code code Significance Significance The extension phone or the main line overtime open circuit The extension phone or the main line...
Page 17
www.cusamintercom.com Setting order order of of of enclosure enclosure station 16.Setting Setting order enclosure station station Order Digital Significance MEMO code code XXXX Confirm manager password before using the order from Confirming manager **00 **00 to **19 password password) (tacitly approves is 2098) Revising manager **01 XXXX...
Page 18
www.cusamintercom.com 1 1 1 7 7 7 . . . Managing Managing center setting order Managing center center setting setting order order Pic2.1 Schematic Introduction Introduction of of of keyboard keyboard Pic2.1 Pic2.1 Schematic Schematic Introduction keyboard 1 1 1 2 2 2 3 3 3 k k k...
Page 19
www.cusamintercom.com Table2.3 Order setting form form of of of managing managing center Table2.3 Table2.3 Order Order setting setting form managing center center Order Order Order Digital code Significance MEMO Digital Digital code code Significance Significance MEMO MEMO code code code XX XXXX XXXX XXXX...
Page 20
www.cusamintercom.com Previse comparative Previse Previse comparative comparative Input Input Input door door door station station station number number number,(Tacitly (Tacitly (Tacitly table table table of of of alarm alarm alarm door door door approves approves is is is 001) 001) approves 001) station...
Page 21
www.cusamintercom.com (2) 、 Use wires accord with the technical specification of our company Cross- Min Cross- Cross- Connect Connect Connect line line line Line Line Line type type type lence lence lence sectional sectional sectional area area area or or or type type of of of wire wire...
www.cusamintercom.com (3) 、 This system is weak power system,so don’t use the same cable with strong power , when it come across strong power,make sure the distance between them is over 30cm or add a severance between them. (4) 、 The wiring connection must be with the same color。Don’t cut off the grounding shielding(iron) wire.If it must be cut off because of construction,then please reconsider after finishing the construction。The iron wire at the bottom of the floor must be grounded。...
Need help?
Do you have a question about the CS-200ZW-1 and is the answer not in the manual?
Questions and answers