or 4B. POWER CORD CONNECTIONS
(3-Wire Connection
Instructions.
For existing
installations ONLY
- Refer to Fig. 13).
1.
Follow
the manufacturer's
installation
instructions
supplied
with the
strain relief and install (Also see Figs. 9, 10 & 1 1).
2.
insert the end connectors
for Line 1, Line 2 and Neutral
and tighten
securely
to the terminal
block
(See Fig. 13).
IMPORTANT
NOTE:
DO NOT LOOSEN
the factory
installed
nut
connections
which
secure
the range wiring
to the terminal
block.
Electrical
failure
or loss of electrical
connection
may occur
if these 3
nuts are loosened
or removed.
3.
Make sure all connections
are tightened
securely
and replace
the rear
access
cover
(See Fig. 9).
Grounding
Instructions
(3-Wire Connections
only): A ground
strap
is installed
on this range which connects
the center
terminal
of the
terminal
block (Neutral)
to the range chassis.
The ground
strap
is
connected
to the range by the center,
lowest screw
(See Fig. 13). The
ground
strap
must not be removed
unless
National,
State or Local
Codes
do not permit
use of a ground
strap.
NOTE:
If the ground
strap is removed
for any reason,
a separate
ground
wire must be connected
to the separate
ground
screw
attached
to the range chassis
and to an adequate
ground
source.
4c. 3 & 4-WIRE
PERMANENT
WIRE
CONNECTIONS.
3 - Wire Permanent Connection - follow
Steps 1,2 & 5 below.
4 - Wire Permanent Connection
- follow
Steps 1 thru 5 below.
Before wiring the range, review the suggested power source location
drawings in Fig. 3. If connecting to a 4-Wire electrical system (new branch-
circuit or mobile home requires 4-Wire connection):
1.
(3 & 4 - Wire
Permanent
Connections)
Follow
the manufacturer's
installation
instructions
supplied
with the strain relief and install.
2.
(3 & 4 - Wire
Permanent
Connections)
Strip insulation
away from the
ends of the permanent
wiring
for Line 1, Line 2, Neutral
(also strip ground
wire on 4-Wire
Connections).
Tighten
all 3 wire leads to the terminal
block (Follow
wire locations
shown
in Fig. 14).
IMPORTANT
NOTE:
DO NOT LOOSEN
the factory
installed
nut
connections
which
secure
the range wiring
to the terminal
block.
Electrical
failure
or loss of electrical
connection
may occur
if these 3
nuts are loosened
or removed.
NOTE:
For 3-Wire
Permanent
Connections
skip
Steps
3 & 4 and continue
with
Step
5.
3.
(4-Wire
Permanent
Connection
ONLY)
Disconnect
the ground
strap.
Remove
the factory
installed
ground
screw
& plate to release
the factory
installed
copper
ground
strap from frame of the appliance.
Cut and
discard
the copper
strap from the terminal
block.
KEEP the ground
screw,
ground
plate and go to Step 4.
4.
(4-Wire
Permanent
Connection
ONLY)
Connect
the ground
wire lead
(Green)
to the frame
of the appliance
using the ground
screw
& plate as
shown
in Fig. 15. Be sure to install using the same
hole in the frame
where the ground
screw was originally
installed.
5.
(3 & 4 - Wire
Permanent
Connections)
Make sure all connections
are
tightened
securely
and replace
the rear access
cover (See Fig. 9).
NOTE:
Non-terminated
field
wire
compression
connections
must
be
set at approximately
22 in./Ibs.
5. CAREFULLYSLIDE
RANGE INTO FINAL LOCATION.
Be sure to provide all the adequate
clearances and dimensions
shown in
Figs. 1, 2 & 3 before moving appliance into final location.
Carefully
slide
range
into final
position
while
inserting
rear leveling
leg into
and FULLY
ENGAGING
THE ANTI-TIP
BRACKET
(See Fig. 7). Make sure the
power
cord folds into the remaining
open floor
area behind
the range Warmer
or storage
drawer.
Be sure to check
the level of the range.
4
3-Wire Connection
Connect
line 1
Terminal
block
3 Factory installed connections
Connect
(DO NOT LOOSEN)
neutral
center) here
Ground strap
Ground screw
Connect
line 2
here
NOTES:
Install strain-relief
bushing. Center or white
wire must always be
attached to the center
terminal on block
Fig. 13
FOR 3 & 4-Wire Permanent Connections
- Tighten all 3
Terminal
wire leads
block
Line 1
Line 2
Ground plate
Ground screw
Ground strap
Fig, 14
GROUND
PLATE_
PROPER
"
_
GROUND
_OR
._A
r_
4.-WlR E
_NE)
PERMANENT
CONNECTION
GROUND
GROUND
SCREW
WIRE LEAD
Fig, 15