HOW TO INSTALL YOUR
WARNING: ALL WIRING AND INSTALLATION MUST BE SUPERVISED BY A
SUITABLY QUALIFIED PERSON.
WARNING: DO NOT INSTALL THIS UNIT WHERE IT MAY BE SUBJECTED TO
FREEZING CONDITIONS.
Diagram 1a
Examples of fitted units
The Powerstream-Eco is recommended to supply a
MAXIMUM of two washbasins (see diagram 1a)
OR a washbasin and shower (see diagram 4b)
If the Powerstream-Eco is connected to a mixer tap
then only NON-Thermostatic types should be used
(water mixes at the outlet pipe only).
The Powerstream-Eco is NOT to be fitted to a
bath or kitchen sink other than for hand-washing purposes.
(See Guarantee exclusions on page 16 and
product flow rate tables on page 14).
The unit MUST NOT be mounted upside down (diagram 1b).
BEFORE YOU START
Check that the mains electric is capable of supplying the required current.
See the rating plate for current requirements.
Check the pressure of the main water supply.
To operate correctly, the unit requires the following running pressures.
Check the rating plate to see which applies:-
Model
10 psi (0.7 bar)
Up to 9.5kW
15 psi (1.1 bar)
Up to 10.8kW
Basin
Minimum
Maximum
150 psi (10.3 bar)
(69 kPa)
(1035 kPa)
150 psi (10.3 bar)
(103 kPa)
(1035 kPa)
POWERSTREAM-ECO
Diagram 1b
Acceptable unit orientation
Dynamic Water Pressure
Minimum
15 psi (1.1 bar)
(103 kPa)
20 psi (1.4 bar)
(138 kPa)
4
Shower
Maximum
150 psi (10.3 bar)
(1035 kPa)
150 psi (10.3 bar)
(1035 kPa)