A.J.Antunes roundup MS-250 Owner's Manual

A.J.Antunes roundup MS-250 Owner's Manual

Miracle steamer
Hide thumbs Also See for roundup MS-250:

Advertisement

MaNufactuRiNg
NuMbeRs:
9100430
9100435
9100436
9100437
9100438
9100460
9100462
9100466
9100468
Miracle SteaMer
Models MS-250/255
C
US
C
US
CM
P/N 1010455 Rev. D 03/12
MS-255 Shown
Owner
s Manual
'

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the roundup MS-250 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for A.J.Antunes roundup MS-250

  • Page 1 MaNufactuRiNg NuMbeRs: 9100430 9100435 9100436 9100437 9100438 9100460 9100462 9100466 9100468 Miracle SteaMer Models MS-250/255 P/N 1010455 Rev. D 03/12 MS-255 Shown Owner s Manual ’...
  • Page 2: Table Of Contents

    Miracle SteaMer table Of cOntents Owner information .............2 Operation ..............9 general ..............2 Operating instructions ..........9 Warranty information ..........2 Programming .............9 Owner information (continued) .........3 Hi-Limit Reset button ..........11 service/technical assistance ........3 status indicator LeDs ..........11 Model Designation .............3 fault codes .............11 specifications .............5 maintenance ..............12 electrical Ratings ............5...
  • Page 3: Owner Information (Continued)

    Miracle SteaMer Owner infOrmatiOn (continued) service/technical assistance use only genuine Roundup replacement parts in this if you experience any problems with the installation or unit. use of replacement parts other than those sup- operation of your unit, contact your local authorized plied by the manufacturer will void the warranty.
  • Page 4 Miracle SteaMer impOrtant safetY infOrmatiOn (continued) in addition to the warnings and cautions in this manual, • This equipment is to be installed to com- use the following guidelines to safely operate the unit. ply with the basic plumbing code of the building Officials and code administrators, • Read all instructions before using equipment.
  • Page 5: Specifications

    Miracle SteaMer specificatiOns electrical ratings electrical cord & plug configurations model mfg. Voltage watts amps Hertz model and Description configuration number mfg. no. Ms-250cV 9100430 3300 15.9 50/60 Ms-250Hc cee 7/7, 16 9100438 amp., 250 Vac Ms-250cV 9100435 3300 15.9 50/60 Ms-255Hc (assembly...
  • Page 6: Installation

    3. Remove all packing materials and protective coverings from the unit. Drawer 4. ms-250: Remove and wash the Wire trivet, spatula, spatula Liner, and Drip Pan (figure 1) in Drip pan soap and water. Rinse with clean hot water and allow to air dry.
  • Page 7 Miracle SteaMer installatiOn (continued) electrical caUtiOn be sure to follow all safeguards and precautions 1. Place the unit on a sturdy, level table or other in the important safety instructions section of this work surface. manual. 2. ensure that the line voltage corresponds to the stated voltage on the units specification label and caUtiOn power cord warning tag.
  • Page 8 Miracle SteaMer installatiOn (continued) caUtiOn caUtiOn water pressure must not exceed 30 psi (2.1 kg/cm 2 this equipment is to be installed to comply with the basic plumbing code of the building Officials or 207 kpa). higher pressure may cause poor per- and code administrators, inc.
  • Page 9: Operation

    Miracle SteaMer OperatiOn programming ready light cYc (total cycle time) refers to the total pro- grammed steam time set for the product. READY shO (shot interval time) refers to the time set message Display between shots of steam during a complete cycle. start/stop h2O setting (steam shot time) refers to the water button...
  • Page 10 Miracle SteaMer OperatiOn (continued) 8. Press and release again and “h2O” will be displayed (figure 6, item g). READY READY 9. to change the H2O (steam shot time), press and 1500 release the prOGram button again to display SINGLE SHOT SINGLE SHOT the setting (Figure 6, Item H). Use ▲ or ▼ to increase or decrease the time.
  • Page 11: Hi-Limit Reset Button

    Miracle SteaMer OperatiOn (continued) hi-limit reset button hi-limit reset button a hi-limit thermostat turns off electrical power to the steam generator if it overheats. to reset this thermo- stat, allow approximately 45 minutes for the unit to power cord cool down, remove the black cap, and then press the Hi-Limit Reset button located on the rear of the unit (figure 7).
  • Page 12: Maintenance

    Hose clamp for leakage. tighten clamps or rinse with clear water, and wipe dry. when replace parts if needed. required, always rub in direction of metal polish 4. ms-250: Remove the spatula, spatula Liner, Drip lines. Pan, top cover, and steam Vent (figure 9). • Routine cleaning should be done daily using ms-255: Remove the Drawer, Drawer Liner with soap, ammonia detergent, and water.
  • Page 13: Monthly

    Miracle SteaMer maintenance (continued) monthly wing nut the Miracle steamer utilizes an open steam generator. Water sprayed onto the generator surface flashes into Generator steam immediately, but the minerals in the water do not cover steam, they stay on the generator surface. a small amount of calcium/mineral deposits are needed for Diffuser proper operation, but a buildup of excessive calcium/...
  • Page 14: Checking And Cleaning The Water Strainer

    Miracle SteaMer maintenance (continued) mesh O-ring screen tubing male Quick strainer cup Disconnect insert figure 12. inlet hose assembly checKinG anD cleaninG the water strainer 3 carefully place the Mesh screen into its seat at the bottom of the strainer cup and confirm that the Water strainer protects your equipment from any the orange O-ring is properly seated in its place foreign debris in the water line that could get into the...
  • Page 15: Troubleshooting

    Miracle SteaMer trOUbleshOOtinG warninG To avoid possible personal injury and/or damage to the unit, inspection, test and repair of electrical equip- ment should be performed by qualified service personnel. the unit should be unplugged when servicing, except when electrical tests are required. problem possible cause corrective action control Display is blank (power is on the power cord is not correctly Plug the power cord into the appro- but indicator light is off).
  • Page 16 Miracle SteaMer trOUbleshOOtinG (continued) problem possible cause corrective action unit heats but there Water Line Valve is closed. check that the Water Line Valve is open. is little or no steam filter strainer is restricted. check and clean the filter strainer as described in produced the Maintenance section of this manual.
  • Page 17 Miracle SteaMer trOUbleshOOtinG (continued) problem possible cause corrective action unit floods overnight and/or solenoid Valve is leaking due attempt to flush the debris out of the valve by continues to steam even when to debris trapped inside the rapidly operating the unit on a number of single in idle mode.
  • Page 18: Replacement Parts

    Miracle SteaMer replacement parts P/N 1010455 Rev. D 03/12 A.J. Antunes & Co.
  • Page 19 Miracle SteaMer replacement parts (continued) P/N 1010455 Rev. D 03/12 A.J. Antunes & Co.
  • Page 20 Housing 72 7000317 control board, 19 0503435 Retainer, thermocouple temperature/timer, 24V, 50/60 Hz 21 0021314 Liner, cavity (Ms-250 only) 74 338P102* bolt, Handle Mounting 21a 0504081 Liner cavity (not shown) (Ms-250 only) for Mfg. No. 9100437 only) 79 0011471 Drawer assy.
  • Page 21 Miracle SteaMer replacement parts (continued) item part Description Qty. Dual water pressure regulator Kit - part no. 7000235 to steamer 7000139 elbow, Quick Disconnect - 1/4” to steamer 2030126 tubing 1/4” i.D. PVc bRD. 24” Long 2030125 tubing 1/4” i.D. PVc bRD. 12” Long 2040150 elbow, Male - Nylon 1/4”...
  • Page 22: Wiring Diagrams

    Miracle SteaMer wirinG DiaGrams *NOte: for 208-240 Vac units, the two primary coils are wired in series with one another. for 120 Vac units, the two primary coils are wired in parallel with one another. P/N 1010455 Rev. D 03/12 A.J.
  • Page 23 Miracle SteaMer nOtes P/N 1010455 Rev. D 03/12 A.J. Antunes & Co.
  • Page 24: Limited Warranty

    limiteD warrantY equipment manufactured by Roundup food equipment Division of a.J. antunes & co. has been con- structed of the finest materials available and manufactured to high quality standards. these units are warranted to be free from electrical and mechanical defects for a period of one (1) year from date of purchase under normal use and service, and when installed in accordance with manufacturer’s recom- mendations.

This manual is also suitable for:

Roundup ms-255

Table of Contents