Download Print this page
Dacor Distinctive DECT304 Installation Instructions Manual
Dacor Distinctive DECT304 Installation Instructions Manual

Dacor Distinctive DECT304 Installation Instructions Manual

Distinctive electric cooktop
Hide thumbs Also See for Distinctive DECT304:

Advertisement

_D
PJ
eo
_o
Lr)
O
Installation
Instructions
Distinctive
TM
Electric
Cooktop
Models DECT304, DECT365
Fran_:is
• voir page 1 1
Espa_ol:
consuhe la p6gina 21

Advertisement

loading
Need help?

Need help?

Do you have a question about the Distinctive DECT304 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Dacor Distinctive DECT304

  • Page 1 Installation Instructions Distinctive Electric Cooktop Models DECT304, DECT365 Fran_:is • voir page 1 1 Espa_ol: consuhe la p6gina 21...
  • Page 2 Table of Contents Page WARNING Special Warnings .............. 3 Product Dimensions and Cutout Requirements ..... 4 This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or Important Preparation Suggestions ........5 hurt you and others. Cooktop installation ............
  • Page 3 DECT304 J(5,18cm) DECT365 Figure 1. Chassis dimensions CUTOUT DiMENSiONS WIDTH OF CUT DEPTH OF CUT SEE NOTE FROM EDGE OF CUTOUT Hole in cabinet AND FRONT EDGE OF floor for conduit 1-1/2" (3.8 cm) COUNTERTOP routing: MIN CLEARANCE 1" (2,5cm) 3 1/2"...
  • Page 4: Cabinet Requirements

    CABINET REQUIREMENTS WALL COVERING CABINETS, AND COUNTERTOP MUST WITHSTAND HEAT UP TO 200°F (93°C) INST 023-2 Fiaure 3. Cabinet dimensions and reauirements CUTOUT WIDTH 28-11/16" i 19-1/4" 130" 30" (76.2 cm) I(49.0 cm) to (72.9 cm) to 18" (45.7 cm) 2"...
  • Page 5 _ Ho [)%LLA Step 1 WARNING Remove packaging materials and literature package from the cooktop before beginning installation. Excessive Weight Hazard Remove installation manual from literature pack and Use two or more people to move and install read them carefully before you begin. cooktop.
  • Page 6 Step 2 Place a towel or table cloth onto the counter top. Lay the cooktop upside down onto the protected surface. BURNER BOX TABLE CLOTH Figure 8 Figure 6 Step 3 Step 5 A foam tape is provided to seal the cooktop edges to Four clamp brackets are provided to clamp the cooktop to the countertop.
  • Page 7 CONDUIT OPENING LOCATIONS OF ALUMINUM A: 12" (30,5 cm) MIN FROM REFLECTIVE TAPE BOTTOM OF COUNTERTOP AND ADJACENT CABINET (RIGHT SIDE) TAPE TOP AND VERTICAL SIDES OF ;UTOUT SOLID SURFACE INST 005-2 COUNTERTOP INSTALLATION Figure 11 ........................INST 030-2 WARNING Figure 10 THE CONDUIT IS 4 FEET LONG...
  • Page 8 Make the electrical connection following the appropriate steps for your installation. 514T40NA Your cooktop must be connected to the proper 30" DECT304 6,7kW 5,03kW I electrical voltage and frequency as specified in the table on the right. 9,4kW...
  • Page 9 Recommended Minimum 3-WIRE CABLE FROM POWER kW Rating on Circuit protection Wire size SUPPLY RED WIRES JUNCTION serial plate in amperes (AWG) 0-4.8 4.9-6.9 7.0-9.9 10.0-11.9 WIRE 12.0-14.9 Be sure your appliance is properly installed grounded by a qualified technician. Ask your dealer to recommend a qualified...
  • Page 10 © © © The Life of the Kitchen? Dacor • 600 Anton Blvd. Suite 1000 Costa Mesa, CA 92626 • Phone: (800) 793-0093 • Fax: (626)403-3130 • www.dacor.com...