Download Print this page

Grounding Instructions - Frigidaire FEFB68CSA Installation Instructions Manual

30" electric range, 3 wire, 60 hz. systems
Hide thumbs Also See for FEFB68CSA:

Advertisement

Available languages

Available languages

Rm'uEaD
Terminal
Line2
Neutral
en_
TO FUSED
DISCONNECT
i/Ak_
BOX OR
_
APPROVED
WIRING DEVICE
FOR COPPER
POWER SUPPLY
CORD.
Figure 2
A,
Remove the 2 screws and remove terminal
box
cover,
B,
Remove the 3 loose nuts (after you removed the
rubber band) on the terminal
block using 3/8"
nut driver or socket.
C, Attach cable or pigtail to the 3 studs on terminal
block, as local codes require. The neutral wire
(white)
or center wire must be connected to
center terminal.
D, Reinstall terminal box cover.
IIl_l_!_r_'_F)o
not loosen nuts which secure the
factory installed range wiring to terminal block while
connecting
range,
Electrical
failure
or loss of
electrical connection may occur.
GROUNDING INSTRUCTIONS
A ground link is installed on this range which connects
the center terminal of the terminal block (neutral) to the
chassis. The ground link is connected to the range by the
center
ground
screw, The ground
link must not be
removed unless national or local codes do not permit use
of the ground link,
NOTE: If the ground link is removed for any reason, a
separate ground wire must be connected to the separate
ground screw attached to the range chassis, and to an
adequate ground source,
If used in a mobile home or if local codes do not permit
grounding
through
the neutral,
use ground
lead or
ground screw to ground
unit in accordance
with local
codes, Connect neutral to branch circuit,
To Remove Ground Link:
1,
Remove
ground
link
screw
using
a Phillips
screwdriver,
Save screw
for future use,
2,
Bend up ground link so
that it does not contact
the range,
7. Wiring Instructions - 4-Wire Supply Cable
(Mobile Homes)
From
t_ge •. i ¸, ,.
Range
!! Silver
i colored
Line
4 WIre
copper
[
i screw
No. 8 green
TO FUSED
Insulated
DISCONNECT
copper
BOX OR
!ground wire
APPROVED
WIRING DEVICE
FOR COPPER
POWER SUPPLY
Figure 3
Remove the 2 screws and remove terminal
box
A,
cover,
B,
Remove ground link from terminal box and from
appliance frame. Retain ground screw.
C, Connect ground
wire (green) of copper power
supply cord to frame of appliance with ground
screw, using hole in frame where ground strap
was removed (see Figure 3).
D, Connect
neutral
(white) wire of copper power
supply cord to center silver colored terminal of
terminal
box, and connect
the other wires to
outer terminals
using the 3 loose nuts on the
terminal
block to terminal
box using 3/8" nut
driver or socket.
E,
Reinstall terminal box cover.

Advertisement

loading

This manual is also suitable for: