Electrical
Requirements
This appliance must be supplied with the proper voltage
and frequency, and connected to an individual, properly
grounded branch circuit, protected by a circuit breaker or
fuse, having amperage as noted on the rating plate (the
rating plate is located on the oven frame).
If local codes permit, you can use a 3-wire single phase
120/208 or 120/240 Volt, 60Hz AC only electrical
system. If you connect to aluminum wiring, properly
installed connectors approved for use with aluminum
wiring must be use.
NOTE: Wire sizes and connections must conform with
the fuse size and rating of the appliance in accordance
with the National Electrical Code ANSI/NFPA No. 70-
latest edition, and local codes and ordinances.
Electrical
Shock
Hazard
, Electrical ground is required on this appliance.
, Do not connect
to the electrical
supply until
appliance is permanently
grounded.
, Disconnect
power
to the junction
box before
making the electrical connection.
, This
appliance
must
be
connected
to
a
grounded,
metallic, permanent
wiring system,
or a grounding
connector should be connected
to the grounding
terminal
or wire lead on the
appliance.
, Do not use a gas supply line for grounding
the
appliance.
Failure to do any of the above could result in a
fire, personal injury or electrical shock.
This appliance is manufactured
with a neutral (white)
power supply wire and a cabinet-connected
green (or
bare copper) grounding wire.
Connect the appliance cable to the junction
box through
the U,L.-listed conduit connector, Complete electrical
connection according to local codes and ordinances. (For
preferredjunction
box location, see Figure 1,)
Where local codes permit connecting the cabinet-
grounding
conductor to the neutral (white)junction
box wire (see Figure 2)
1. Disconnect the power supply.
2, In the circuit breaker, fuse box orjunction
box:
connect the appliance and the residence cable wires
as shown in figure 2,
White Wire
(Neutral)
Cablefrom
Residence
Wires I
Box
(Neutral)
Green
U.L.-listed
(or Bare Copper)
Conduit
Wire
Cable from
Connector
Range
(or CSA listed)
Figure
2
3-Wire
(Grounded
Neutral)
Electrical
System
(Example:
Junction
Box)
3