Frigidaire FGF312ASA Installation Instructions Manual page 6

30" gas range with electric ignition or standing pilot
Hide thumbs Also See for FGF312ASA:
Table of Contents

Advertisement

Grounding Instructions
The power cord of this appliance is equipped with
a 3Iprong
(grounding) p lugwhichmateswitha standard 3-pronggrounding
wall receptacle to minimize the possibilityof electric shock
hazard from this appliance. The customershould have the
wall receptacle and circuitchecked bya qualifiedelectrician
tomake surethereceptacle ispropedygroundedand poladzed,
Preferred Method
Not, Under
Power Supply
Grounding
Cord with
Type
3-Prong
Wall
Grounding
Receptacle
Plug
Where a standard two-prongwall receptacle is encountered,
itisthe personal responsibility and obligationofthecustomer
tohave it replacedwith a properlygroundedthree-prong walt
receptacle.
DO NOT, UNDER ANY CIRCUMSTANCES,
CUT OR
REMOVE THE THIRD (GROUND) PRONG FROM THE
POWER CORD.
This range is equipped with either an electric ignition
system or standing pilots. To determine which system
your range has, lift the cooktop. Models with standing
pilots will have pilot cups as pictured in step 6b. Follow
the appropriate instructions for your model.
Operation of Surface Burners
Venturi
Style
Bar
6a.
Electric
Ignition
Surface
Burners
Operation of electric ignitersshould be checked after range
and supply lineconnectorshave been carefully checked for
leaks and range has been connected to electric power. To
check for proper lighting,push in and turn a surface burner
knob to the LITE position. You willhear the igniter sparking.
The surface burner should lightwhen gas is available to the top
burner. Each burner should light within four (4) seconds in
normal operation after air has been purged from supply lines.
Visually check that burner has lit. Once the burner lights, the
control knob should be rotated out of the LITE position. There
are separate ignition devices for each burner. Try each knob
separately until all burner valves have been checked.
Note: Knob styles may varyfrom those pictured below.
'
I'
/
J
''111
Knob Used
KnobUsed
withTwo
withLinear
Position Valve
FlowValve
6b.
Standing
Pilot Surface
Burners
After range and supply line conduits have been carefully
checked for leaks, purge air from the system, The standing
pilotsmust be lit immediately,proceed as fellows:
1.
Raise the cooktop.
2.
Light both pilots with a match. When both pilots are lit,
adjust the top pilot adjustment until the pilots are
approximately 1/8" above the pilotcage witha very slight
yellow tip.
Pilot
Cage
1/8" Above
Pilot
t
Cage
CheckSurface Burners
To check for proper lighting, push in and turn a surface burner
knobtothe LITE position.Eachburnershouldlightwithinfour
(4) seconds in normal operation.Once the burner lights,the
knob should be rotatedoutofthe LITE position. Try each knob
separately until all burnervalves have been checked.

Advertisement

Table of Contents
loading

Table of Contents