Frigidaire FGF312ASA Installation Instructions Manual page 5

30" gas range with electric ignition or standing pilot
Hide thumbs Also See for FGF312ASA:
Table of Contents

Advertisement

Gas connection
for electric ignition models
Manual
Flare
Flexible
Flare Union
Pressure
Shutoff
Union
Appliance
Adaptor
Regulator
Valve
_
Conduit
off
Service Shut-Off Valve ElectricIgnition models only -_
(Shown in ON Position).
Besure lever is in the "On" position when
installation is complete
Gas connection for pilot models
Manual
Flare
Flexible FlareUnion Pressure
Shutoff
Union
Appliance
Adaptor
Regulator
Valve
|
Conduit
ON
a) Install an external manual gas shut-off valve to gas supply
line in an easily-accessible location outside of the range.
Be sure you know how and where to shut-off the gas
supply to the range.
b)
Install 1/2" flare union adapter to pressure regulator.
c)
Attach appliance conduit to flare union on regulator.
d)
Install flare union adapter to external manual shut-off
valve.
e) Attach appliance conduit to flare union on shut-off valve.
f)
Make sure service shut-offvalve on pressure regulator is
in "ON" position.
g) Check for leaks. Turn the gas supply on to the range and
use a liquid leak detector at all joints and conduits to
check for leaks in the system.
Do not use a flame to check for gas leaks.
Checking Manifold Gas Pressure
Disconnect the range and its individual shut-off valve from the
gas supplypiping system duringany pressure testingofthat
system at test pressures greater than 14" of water column
pressure(approximately 1/2" psig).
The appliance must be isolated from the gas supply piping
system by closing its individual manual shut-off valve during
any pressure testing of the gas supply piping system at test
pressures equal to or less than 14" of water column prassu re
(approximately 1/2" psig).
If it should be necessary to check the manifold gas pressure,
connect manometer (water gauge) or other pressure device to
the top burner right rear orifice. Using a rubber hosewith inside
diameter of approximately 1/4," hold tubing down tight over
orifice. Turn burner valve on.
Foran accurate pressure check have at least two (2) other top
burnersburning. Be sure the gas supply(inlet) pressure isat
leastone inchabove specified rangemanifoldpressure.The
gas supplypressure shouldnever be over 14"water column.
When properlyadjustedfor NaturalGas the manifoldpressure
is 4." (For LP/Propane Gas the manifoldpressure is 10.")
Read electrical connection details belowand
connect electricity to range.
Before servicing, disconnect electrical
supply at circuit breaker, fuse or power cord,
Electric Requirements: An individual, properly grounded and
poladzed branch circuit protected by a 15 amp. circuit breaker
or time delay fuse. See serial plate for proper voltage.
Ext n i n ordPr c
ti n :
Because of potentialsafety hazards undercertain conditions,
we strongly recommend against the use of any extension
cord. However, if you still elect to use an extension cord, it is
absolutely necessary that it be a UL listed 3-wire grounding
type appliance extension cord and that the current carrying
rating of the cord in amperes be equivalent to or greater than
the branch circuit rating. Such extension cords are obtainable
through your local service organization.
PLEASE READ CAREFULLY! For personal
safety, this product must be properly grounded.
5