10
INSTALL HANDLES
See separate installation instructions supplied with handle kits for installing handles onto fitting.
11
TEST INSTALLED FITTING
With HANDLES (1) in OFF position, turn on WATER
SUPPLIES (2) and check all connections for leaks.
Remove AERATOR (3).
Operate both HANDLES (1) to flush water
lines thoroughly.
Replace AERATOR (3).
12
CHECK DRAIN CONNECTIONS
Operate POP-UP KNOB (5) and fill Sink with water. Check
that DRAIN STOPPER (4) makes a good seal and retains
water in Sink. If STOPPER (4) does not seal properly, please
refer to "Troubleshooting Guide" in these instructions.
Release POP-UP KNOB (5) down and check all drain
connections and "P" trap for leaks.
if necessary.
TO CLEAN AERATOR
AERATOR (3) may accumulate dirt causing distorted
and reduced water flow. Unscrew and remove
AERATOR (3) and rinse clean.
Replace AERATOR (3) and operate handles several times
from OFF to ON position. Do not force, handles turn only 90˚.
13
CARE INSTRUCTIONS:
DO: SIMPLY RINSE THE PRODUCT
CLEAN WITH CLEAR WATER. DRY
WITH A SOFT COTTON FLANNEL
CLOTH.
DO NOT: DO NOT CLEAN THE
PRODUCT WITH SOAPS, ACID,
POLISH, ABRASIVES, HARSH
CLEANERS, OR A CLOTH WITH
A COARSE SURFACE.
Tighten
14
SERVICE
To change direction of handle rotation,
proceed as follows
:
Turn valve to OFF position. See handle instructions
with handle kit for removing handles.
Remove ADAPTER SCREW (1) and pull of ADAPTER (2).
Remove SPRING CLIP (3). Lift STOP WASHER (4),
turn 90° and replace. Replace SPRING CLIP (3).
Replace handle assembly. See handle instructions
with handle kit for installing handles.
4
1
WASTE
OUTLET
HOT
2
HANDLE
ASSEMBLY
5
1
4
2
COLD
"P" TRAP
90˚
4
4 3 1 6 7 R e v. 1 . 3
3
1
2