Installation
[_] CONNECTING
INLET HOSES
(on some models)
To produce steam, the drger must connect to the cold
water supplg. Since the washer must also connect to the
cold water, a "`7"connector is inserted to allow both inlet
hoses to make that connection at the some time.
NOTE: Use the new inlet hoses provided; never
use old hoses.
1. Turn the cold water faucet off. Remove the washer inlet
hose from the washer fill valve connector (cold).
2. Ensure the rubber fiat washer is in place and screw
the female coupling of the short hose onto the washer fill
valve connector. Tighten bg hand until firmlg seated.
3. Attach the female end of the ",7" connector to the male
coupling of the short hose. Ensure the rubber fiat washer
is in place. Tighten bg hand until firmlg seated.
4. Insert the filter screen in the coupling of the washer's
inlet hose. If a rubber fiat washer
is alreadg in place remove it before installing
the filter screen. Attach this coupling to one male end of
the "`7"connector. Tighten bg hand until firmlg seated.
5. Ensure the rubber fiat washer is in place and attach
the drger's long inlet hose to the other male end of the
"`7"connector. Tighten bg hand until firmlg seated.
6. Ensure the rubber fiat washer is in place and attach
the other end of the drger's long inlet hose to the fill valve
connector at the bottom of the drger back panel. Tighten
bg hand until firmlg seated.
7. Using pliers, tighten all the couplings with
an additional two-thirds turn.
NOTE: Do not overtighten. Damage to the couplings mag
result.
Instructions
[_ CONNECTING
INLET HOSES {cont.}
8. Turn the water faucet on.
9. Check for leaks around the '"7" connector,
faucet and hose couplings.
WATER SUPPLY REQUIREMENTS
Hot and cold water faucets MUSTbe installed within z_2
in. (107 cm) of gour washer's water inlet. The faucets
MUSTbe 3//4 in. (1.9 cm) garden hose-tgpe so inlet hoses
can be connected. Water pressure MUSTbe between 10
and 120 pounds per square inch. ,Tour water department
can advise gou of gour water pressure.
NOTE:A water softener is recommended to reduce
buildup of scale inside the steam generator if the home
water supplg is verg hard.
[_]SERVICING
WARNING-
LABEL ALL WIRES
PRIOR TO DISCONNECTION
WHEN
SERVICING CONTROLS.
WIRING
ERRORS
CAN CAUSE IMPROPER AND DANGEROUS
OPERATION
AFTER SERVICING/
INSTALLATION.
For replacement parts and other information, refer to
Owner's Manual for servicing phone numbers.
For Questions on Installation, Call: 1-800-626-2000 (US)or
1-800-561-33/4/4
(Canada).
9