Installation
_] RECONNECTING
GAS
Listed connector
ANSI
Z2!.24
/ CSA 6.!0
1/8" NPT PIPE
NEW METAL
PLUG FOR
GAS
FLEXIBLE GAS
INLET PRESSURE
LINE CONNECTOR
ADAPTER
ELBOW
3/8" NPT
SHUT-OFF
PIPE SIZE
ITEMSNOT SUPPLIED
_AT
LEAST1/2"
Note: The connector and fittings (]re designed for use
onlg on the original installation and (]re not to be reused
for another appliance or at another location. Keep flare
end of adaptor free of grease, oil and thread sealant.
Caution: Use adapters as shown. Connector nuts must
not be connected directlg to pipe threads.
APPLYPIPECOHPOUND
TOTHE ADAPTER AND
DRYER GASINLET.
TIGHTEN THE FLEXIBLE
GAS LINE USING TWO
ADJUSTABLE
WRENCHES.
Instructions
APPLYPIPECOMPOUND
TO ALL HALE THREADS.
TIGHTEN ALL CONNECTIONS
USING TWO ADJUSTABLE WRENCHES.
DO NOT OVERTORQUE GAS CONNECTIONS!
[-4] LEAK TEST
"WARNING:
NEVERUSEAN OPEN
LAME TO TEST FOR GAS LEAKS.
OPEN
GASVALVE,
Check oil connections
for teaks with soopg solution or equivalent.
Apptg soop solution. Leak test solution
must not contain
ammo-
nia which could cause damage to the brass fittings.
If leaks ore
found, close volve, retighten the joint, and repeGt the soap test.