Installation
Instructions
[]
3-WIRE CONDUIT
INSTALLATION
[]
Loosen the 3 lower terminal
screws
from
the terminal
block, Insert the center
bare
wire
(white/neutral)
tip through
the bottom
center terminal
block opening.
On certain
models,
the wire will
need to be inserted
through
the ground
strap opening
and
then
into the bottom
center
block opening.
Insert the two side bare wire tips into the
lower
left and the lower
right terminal
block openings.
Tighten
the screws
until
the wire
is firmly
secured
(35 to 50 inch-
Ibs.). Do not overtighten
the screws
since
it could
damage
the wires.
NOTE: ALUMINUM
WIRING:
Aluminum
building
wire may be used but
it must
be rated for the correct
amperage
and voltage
to make connection.
Connect
wires
according
to this step for 3-wire
conduit
or the next step for 4-wire
conduit.
Terminal
_.l_a_
_
_
::ti s
Brack_
Conduit
Wire used, location
and enclosure
of splices, etc., must conform to good
wiring
practices and local codes.
[]
Re-install
the junction
block acces cover
making
sure that wires
do not become
pinched
between
wire
cover and
mainback.
[]
[]
4-WIRE CONDUIT INSTALLATION
Loosen
the three
lower terminal
screws
from the terminal
block.
Remove
the
ground
screw
and ground
plate and retain
them.
Cut and discard
the ground
strap.
DO NOT DISCARD
ANY SCREWS.
Insert the ground
bare wire tip between
the range frame
and the ground
plate
(removed
earlier)
and secure
it in place
with the ground
screw
(removed
earlier).
Insert the bare wire (white/neutral)
tip
through
the bottom
center
of the terminal
block opening.
Insert the two side bare
wire tips into the lower
left and the lower
right terminal
block openings.
Tighten
the
screws
until the wire
is firmly
secured
(35
to 50 inch-lbs.)
Do not overtighten
the
screws
since it could
damage
the wires.
Before
__,___,_
Term 'na IJ/_/_
_
block
Ground strap /"i
After
,_round
strap
__rai_°r
_L_
terminal
Terminal
block
Wire tips
[]
Ground
screw
Ground
plate
(grounding
to range)
Bracket
Wire used, location
and enclosure
of splices, etc., must
conform to good
wiring
practices and local codes.
Re-install
the junction
block access cover
making
sure that wires
do not become
pinched
between
wire
cover and
mainback.