Commissioning
10 Turn the boiler OFF and ON positioning the
function selector 8 as indicated in Fig. 7.9
10
9
Fig. 7.9
11 Keep pressed the reset button 7 for about 10
seconds until the lock--- out signal lamp 6
blinks.
Note: during the adjustment the boiler doesn't op-
erate.
12 Press the reset button 7 repeatedly (2 times)
until the lamps 10 give the indication as in
Fig. 7.10 (useful c.h. output adjustment
mode).
Where:
Fig. 7.10
13 Turn the knob 9 to the minimum (fully counter-
clockwise) and then on the position correspon-
ding to the position obtained on step 8.
By turning the knob 9, the lock--- out signal
lamp 6 blinks quickly (2 per second) indicating
that the setting has changed and must be me-
morised by keeping pressed the reset button
7 for about 5 seconds until the lamps 10 all
briefly simultaneously blink.
14 To reset the boiler to the normal operation turn
it OFF and ON by the function selector 8. In any
case, the boiler automatically resets to its nor-
mal operation after 10 minutes.
36
kW
33
31
29
8
7 6
27
25
23
21
19
17
15
13
11
9
Fig. 7.11
kW
32
30
28
26
Lamp OFF
24
Lamp ON
22
20
18
16
14
12
10
Fig. 7.12
1 2 3 4 5 6 7 8 9 10 11 12 13
M96.24SM/...
M96.28SM/...
M96.32SM/...
5 7 9 11 13 15 17 19 21 23 25 27 29
M96.24SM/...
M96.28SM/...
M96.32SM/...
Natural (G20)
mbar
Butane (G30)
mbar