Calibration / Set-up

It is important to carefully calibrate and set-up the instrument. The
values are stored in a non volatile memory.
To access calibration PAGE, press and hold SET more than 2
seconds.
To select a calibration code, press DOWN, PLUS and MODE as
required.
To return to normal operation mode, press SET when the text
return [rEt] is displayed.
The calibration routines are divided into four groups:
C10 - C17 = USR, User settings.
C20 - C24 = BSP, Log transducer and temp calibrations.
C30 - C37 = HDC, Compass settings.
C70 - C74 = CON, Configuration of the NX2 system.
To change a calibration value, press SET.
To select calibration value, press DOWN, PLUS and PAGE as
required.
To lock the selected value, press SET.
5.1

C10 User settings

To return to normal mode, press SET when the text [rET] is
displayed.
5.1.1

C11 Select the dampening

The dampening will effect wind angle, wind speed, boat speed and
VMG. Dampening is between d0 (0s) and d9 (1'20).
To change the dampening, press SET and change with PLUS or
MINUS and enter with SET.
5.1.2
C13 Displaying boat speed, trip log and temperature,
When set to OFF, the functions will be removed from the display.
The Compass Data instrument may still operate as a Server in the
Nexus Network, transmitting the log and temperature data to other
NX2 instruments without having the information displayed on this
instrument.
5.1.3

C14 Display NAV functions, option

NAV functions are only useful when the Compass Data is
connected in a Nexus Network with Compass transducer and a
navigator. The selection NAV On will add the functions that is
avaliable from the Nexus Network, such as BTW, XTE etc.