MK Diamond Products MK-2000 PRO Series Owner's Manual & Operating Instructions page 36

Brick saw
Table of Contents

Advertisement

MAINTENANCE AND TROUBLESHOOTING
Phillips
Screwdriver
Once Screws removed
go to Step H
(G)
Remove the 3 Pump Casing
Retaining Screws
NOTE: "Rodding" cooling channels is performed by inserting a small wire rod through the cooling inlet on top
of the Blade Guard and directing the rod out through each of the cooling flow tubes located on the
underside o the Blade Guard. The cooling channels should be "rodded" until all ports are free of
foreign debris.
Cooling Flow
Control Valve
(J)
Attach the Flow Control Valve
to the Intake Fitting and check
flow (See Step C)
MK-2000 Pro
Check Impeller
for damage
Check for
restriction
Remove the Pump Casing and
check for restriction; check
Impeller damage
Go to
Go to
Step N
Step O
Rod Cooling Channels and
recheck flow; if after performing
Steps A to N flow still does not
exist, go to Step L
Revision 01/02, Effective Date January 10, 2002
Cooling Flow
Control Valve
If no damage
or restrictions,
go to Step I
clockwise to loosen
(H)
remove the Flow Control Valve
Rod
Channels
(K)
3/4- inch
Wrench
Go to
Turn counter-
Step M
(I)
Using a 9/16-inch wrench,
from the Blade Guard
Return to
MK Diamond
for Repair
(L)
Return to MK Diamond
Page 36

Advertisement

Table of Contents
loading

Table of Contents