MOTOR BRUSH CHANGE-OUT
WARNING
!
Disconnect the tool before servicing and when changing accessories, such as blades, bits, cutters, and
the like.
1. Unplug the PX-3 from its power source and set it up for operation (See Setup, Adjustment and Operation)
One on either
side of motor
(A)
Locate and remove one Motor
Cap Brush
NOTE:
When installing Motor Brushes, care must be teken to ensure the Spring End is straight before
installing the Motor Brush Cap.
PX-3
MAINTENANCE AND TROUBLESHOOTING
Remove the Motor Brush.
Clean the Brush Housing
(D)
Install the Motor Brush Cap
Revision 01/04, Effective Date January 23, 2004
(B)
(E)
Change the second
Motor Brush by repeating
steps (A) to (D)
(C)
Align and install the new
Motor Brush
21