Using the Microphone CONTROL Modes Understanding the PIP Feature Locking and Unlocking the Front Panel Freezing the Image Displaying a Blank Screen Configuring and Controlling the VP-725XLA Configuring the VP-725XLA via the OSD MENU Screens 8.1.1 The Input Screen 8.1.2 The Picture Screen 8.1.3 The Output Screen 8.1.4...
Page 3
Figure 27: Infrared Remote Control Transmitter Figure 28: TextOverlay Application Screen Tables Table 1: Front Panel VP-725XLA Presentation Switcher / Scaler Features Table 2: Rear Panel VP-725XLA Presentation Switcher / Scaler Features Table 3: RGBS and RGsB PINOUTS Table 4: The Operation Modes...
Page 4
Table 19: Infrared Remote Control Transmitter Functions Table 20: Features and Functions of the TextOverlay Application Table 21: Technical Specifications of the VP-725XLA Table 22: Technical Specifications of the RGBHV / RGBS (PC) / RGsB (PC) Input Signal Table 23: Technical Specifications of the Y/C, Video Signal...
Rack Adapters; GROUP 11: Sierra Products 2 We recommend that you use only the power cord that is supplied with the machine 3 Download up-to-date Kramer user manuals at http://www.kramerelectronics.com 4 The complete list of Kramer cables is on our Web site at http://www.kramerelectronics.com...
Page 6
Getting Started KRAMER: SIMPLE CREATIVE TECHNOLOGY...
Overview Overview The VP-725XLA is a presentation scaler/switcher with multiple signal format sections and balanced stereo audio. The unit has five independent 4x1 video sections: composite, s-Video (Y/C), component (RGB), computer graphics, and HDMI, plus a single USB input. Each section can be operated as an individual switcher contained in one box.
Page 8
Overview In addition, the VP-725XLA: • Features Projector Anywhere™ technology – horizontal and vertical geometry controls that compensate for off-axis projector placement • Supports a wide choice of computer graphics output resolutions up to WUXGA/1080p, plus user-definable custom output resolutions...
Page 9
(often associated with low quality cables) • Avoiding interference from neighboring electrical appliances, making sure not to block the ventilation holes, and positioning your VP-725XLA away from moisture, excessive sunlight and dust...
High-Definition Multimedia Interface (HDMI) is an uncompressed all-digital audio/video interface, widely supported in the entertainment and home cinema industry. It delivers the highest high-definition image and sound quality. Note that Kramer Electronics Limited is an HDMI Adopter and an HDCP Licensee. In particular, HDMI •...
Your VP-725XLA Presentation Switcher / Scaler Table 1: Front Panel VP-725XLA Presentation Switcher / Scaler Features Feature Function Selects one of the s-Video (Y/C) sources (from 1 to 4) Selects one of the CV sources (from 1 to 4) UXGA...
Page 13
Figure 2 Table 2 define the rear panel of the VP-725XLA: 1 Only one of the group buttons can be ON, or all buttons can be OFF (pressing a button will select that button, and turn OFF the previously selected button. If the selected button is pressed, it will turn it OFF)
Up to four HDMI sources (for example, DVD players) to the HDMI connectors 1 Switch OFF the power on each device before connecting it to your VP-725XLA. After connecting your VP-725XLA, switch on its power and then switch on the power on each device...
Page 18
Connecting the VP-725XLA Presentation Switcher / Scaler 2. Connect one or more of the following balanced stereo audio sources UXGA sources 1 to 4 to the UXGA AUDIO INPUT terminal block connectors (from 1 to 4) CV sources 1 to 4 to the CV AUDIO INPUT terminal block connectors (from 1 to 4) ...
Connecting the VP-725XLA Presentation Switcher / Scaler 6.2 The RGBS and RGsB PINOUTs Table 3 defines the input progressive and interlaced RGBS and RGsB pinouts: Table 3: RGBS and RGsB PINOUTS Input Color Space PINOUT RGsB Red to PIN 1...
Ethernet configuration. 6.4.1 Connecting the Ethernet Port directly to a PC (Crossover Cable) You can connect the Ethernet port of the VP-725XLA to the Ethernet port on your PC, via a crossover cable with RJ-45 connectors. This type of connection is recommended for identification of the factory default...
6. Click OK. 6.4.2 Connecting the Ethernet Port via a Network Hub (Straight-Through Cable) You can connect the Ethernet port of the VP-725XLA to the Ethernet port on a network hub or network router, via a straight-through cable with RJ-45 connectors.
Operating the VP-725XLA Presentation Switcher / Scaler Operating the VP-725XLA Presentation Switcher / Scaler The VP-725XLA includes the following front panel buttons: • A set of 21 INPUT SELECTOR buttons • A set of Video Group and Audio Group SELECT buttons...
Operating the VP-725XLA Presentation Switcher / Scaler Table 4: The Operation Modes Five Independent One Scaler Switchers VIDEO AUDIO SCALER MASTER Definition GROUP GROUP AUDIO Video only: switch the video signal of the input to the output in each of the five Video Groups...
The Audio follows the video. 7.2.2 Switching the VP-725XLA as a Scaler To operate the VP-725XLA as a scaler, press the SCALER button and then switch one of the 21 inputs to the scaled video outputs. If you also press the MASTER AUDIO button, the audio follows the scaled video output.
Operating the VP-725XLA Presentation Switcher / Scaler When the VP-725XLA is in use, both modes operate simultaneously, as well as independently, that is, the Scaler output is available even when switching in the VIDEO GROUP mode, and visa-versa. 7.3 Understanding the Audio Features This section describes: •...
Operating the VP-725XLA Presentation Switcher / Scaler For example, if CV input 3 audio level is set to 2 in the AUDIO GROUP mode, and then you set it at 5 in the MASTER AUDIO mode, the audio level will still be 5 (not 2) when returning to the AUDIO GROUP mode.
Operating the VP-725XLA Presentation Switcher / Scaler 7.4 Understanding the PIP Feature The Picture-in-Picture inserter (PIP) applies to the Scaler operation mode and is used for the simultaneous display of video and graphic sources, and lets you display: • An inserted video source PIP over a graphic source •...
Operating the VP-725XLA Presentation Switcher / Scaler Move the position of the PIP by: • Using the OSD menu (see section 8.1.4) Choose a new PIP source by: • Pressing the "PIP Source" button on the remote control transmitter followed by the button of the desired PIP input •...
Configuring and Controlling the VP-725XLA Configuring and Controlling the VP-725XLA This section describes how to configure and control the VP-725XLA via the: • OSD menu (see section 8.1) • LCD display (see section 8.2) • Infrared remote control transmitter (see section 8.3) You can also control the VP-725XLA via the Ethernet (see section 8.4)
Configuring and Controlling the VP-725XLA 8.1.1 The Input Screen Figure 13 Table 6 define the Input screen. Figure 13: Input Screen Table 6: Input Screen Functions Setting Function Selection/Range Default Select Select the group Video Group, Scaler Scaler VGA Group...
Configuring and Controlling the VP-725XLA Setting Function Selection/Range Default V-Zoom Vertical zoom -8 to 8 Zoom Set the Zoom 100%, 150%, 200%, 225%, 250%, 275%, 300%, 100% 325%, 350%, 375%, 400%, Custom Custom Set the Zoom From 0 to 32 (this range is equivalent to 100% to...
Configuring and Controlling the VP-725XLA Setting Function Selection/Range Default V-Position Set the vertical position of the PIP 0 to 128 on the display H-Size Set custom size 1 to 255 V-Size Set custom size 1 to 255 Frame Turn the PIP frame on or off...
Configuring and Controlling the VP-725XLA Setting Function Selection/Range Default Audio Level Adjust the audio input and output VGA Grp In VGA Grp Out gains for each group (see Figure HDMI Grp In HDMI Grp Out Comp Grp In Comp Grp Out...
Configuring and Controlling the VP-725XLA 8.1.6 The Geometry Screen Figure 19 Table 11 define the Geometry screen, allowing the user flexibility in positioning his projector relative to the screening surface. Figure 19: Geometry Screen Table 11: Geometry Screen Functions Setting...
Configuring and Controlling the VP-725XLA Table 12: Available Settings for Each Application Application Available Settings Keystone Location, horizontal keystone, vertical keystone, pincushion/barrel and Reset all Anyplace Location, Diagonal Projection and Reset all Rotation Location, pincushion/barrel, Rotation and Reset all 8.1.7...
Normal Behavior 8.1.8 The Slideshow Feature The VP-725XLA lets you run a slideshow via the USB input and set the slideshow speed via the slideshow feature. To prepare a slideshow: 1. Load the slideshow JPEG images to a USB memory stick.
Configuring and Controlling the VP-725XLA 8.1.8.1 The Advanced Setup Screen Figure 21 Figure 24, and Table 15 Table 18 define the Advanced Setup screens. Figure 21: Advanced Setup Screen The Mode Set functions define the desired working resolution and refresh rate...
Configuring and Controlling the VP-725XLA Table 16: Misc Functions Setting Function Selection/Range Default Logo Choose ON for the start up logo On, Off or Custom Kramer Logo to appear on the screen (On) OFF for it not to appear Set to Custom to download a...
Configuring and Controlling the VP-725XLA Figure 23: Input Setup Screen Table 17: Input Functions Setting Function Range Default Horizontal Total 1344 Horizontal sync pulse width Horizontal active start point Horizontal active region 1024 Horizontal polarity Vertical Total Vertical sync pulse width...
Configuring and Controlling the VP-725XLA Table 18: Output Functions Setting Function Range Default Horizontal total 1344 Horizontal sync pulse width Horizontal active start point Horizontal active region 1024 Horizontal polarity Vertical total Vertical sync pulse width Vertical active start point...
Keystone to 6 via the LCD Display, using the front panel buttons, do the following: 1. Turn the VP-725XLA unit ON, and press the OSD ON button (if selected) to deselect it. 2. Press the appropriate front panel OSD buttons (as defined in Figure 26).
Configuring and Controlling the VP-725XLA Table 19: Infrared Remote Control Transmitter Functions Function Freeze Pauses the output video Power Cycles power Toggles between a blank screen (blue or black Blank screen) and the display Mute Mutes the audio output Routes the combined signals from the Mic and the...
Text Overlay Application Screen: Figure 28: TextOverlay Application Screen 1 Or connect the serial port of your VP-725XLA to the serial port of your PC (see section 6.3) 2 You can download the latest software from our Web site:...
Click to save the current setting 1 Or search the IP address 2 You have to select the connection type before connecting the software to the machine 3 For example, set to 2 to repeat the text twice KRAMER: SIMPLE CREATIVE TECHNOLOGY...
10 Technical Specifications Table 21 includes the technical specifications: Table 21: Technical Specifications of the VP-725XLA INPUTS: 4 x CV 1Vpp/75Ω on BNC connectors; 4 x YC 1Vpp (Y) 0.3Vpp (C)/75Ω on 4-pin connectors; 4 x Component (Y/G, Pb/B, Pr/R or RGsB ) on BNC connectors;...
YPbPr 1080i YPbPr 1080p YPbPr 1080p YPbPr 1080P 24fps YPbPr 720p YPbPr 720p YPbPr 480i YPbPr 480p YPbPr 576i YPbPr 576p YPbPr 1 For the most up-to-date resolution list, go to our Web site at http://www.kramerelectronics.com KRAMER: SIMPLE CREATIVE TECHNOLOGY...
VESA 1600x1200 VESA 1024x768 1920x1080 VESA 1024x768 VESA 1920x1200 VESA 1024x768 VESA 1680x1050 VESA 1280x720 VESA 1080i 1280x768 1080i 1280x768 VESA 720p 1280x800 VESA 720p HDMI 1280x1024 480p 1280x1024 VESA 576p 1280x1024 VESA 1080p 1366x768 1080p KRAMER: SIMPLE CREATIVE TECHNOLOGY...
VP-725XLA Communication Protocol 11 VP-725XLA Communication Protocol Communication Confirmation: Send: Reply: CR> Set and Get command: Set Command: YControl_TypeFunctionParamCR Reply: ZControl_TypeFunctionParamCR> Get Command: YControl_TypeFunctionCR Reply: ZControl_TypeFunctionParamCR> Example 1 (select VGA1 as video input channel): "Y01570CR" "Z01570CR>" Example 2 (get selected current input channel): "Y...
VP-725XLA Communication Protocol Table 28 includes the Communication Protocol: Table 28: Communication Protocol of the VP-725XLA Control Type Function Parameter Description 0: Auto 1: RGB Input Color Format 2: YUV 0: Auto 1: NTSC 2: PAL 3: PAL-M Input Video Standard 4: PAL-N 5: NTSC 4.43...
Page 57
VP-725XLA Communication Protocol Control Type Function Parameter Description 0: Dynamic Audio Delay 1: User Define 0~340 (step 2) Audio User Delay 0: No audio 1: VGA1 2: VGA2 3: VGA3 4: VGA4 5: HDMI1 6: HDMI2 7: HDMI3 8: HDMI4...
Page 58
VP-725XLA Communication Protocol Control Type Function Parameter Description 0: Profile 1 1: Profile 2 2: Profile 3 3: Profile 4 Recall Setting 4: Profile 5 5: Profile 6 6: Profile 7 7: Profile 8 0: Off Frame Lock 1: On...
Page 59
VP-725XLA Communication Protocol Control Type Function Parameter Description Volume- (left - button) Volume+ (right + button) Enter Picture Swap 0: Off Mute 1: On 0: Off Lock 1: On 0: 640x480 60 1: 640x480 67, Mac13 2: 640x480 72 3: 640x480 75...
Page 60
VP-725XLA Communication Protocol Control Type Function Parameter Description 48: 1080p 49: 1280x800 60 50: 1440x900 51: 1440x900 60(R) 52: 1280x768 53: 1680x1050 60 (R) 54: 1366x768 55: 1366x768 60 (R) 94: Custom1 95: Custom2 96: Custom3 97: Custom4 98: No Input detected...
Page 62
VP-725XLA Communication Protocol Control Type Function Parameter Description 0: Negative polarity Advance Output Mode: HP 1: Positive polarity 384~2047 Advance Output Mode: VT 2~(HS-13) Advance Output Mode: VW 15~(VT-VA-1) Advance Output Mode: VS 480~1200 Advance Output Mode: VA <= (VT-16)
Page 63
VP-725XLA Communication Protocol Control Type Function Parameter Description 3: HDMI4 Error when SELECT ≠ Video Group / Audio Group / AV Group Select COMP group channel 0: COMP1 1: COMP2 Note : 2: COMP3 Error when SELECT ≠ Video Group / Audio...
Page 64
VP-725XLA Communication Protocol Control Type Function Parameter Description 2: 1/9 (for Get Command) Note: For set function command, parameter will 3: 1/4 (for Get Command) be ignore Hot key Master Audio, same as remote control / Keypad - Master Audio of SELECT...
VP-725XLA Communication Protocol 11.1 Error Codes Table 29: The Error Codes Error code Description ERR 1 Unknown command ERR 2 Unknown function ERR 3 Unavailable function ERR 4 Unknown control type ERR 5 Unavailable get function ERR 6 Unavailable set function...
Page 66
EXCLUSION OF DAMAGES The liability of Kramer for any effective products is limited to the repair or replacement of the product at our option. Kramer shall not be liable for: 1. Damage to other property caused by defects in this product, damages based upon inconvenience, loss of use of the product, loss of time, commercial loss;...
Page 67
For the latest information on our products and a list of Kramer distributors, visit our Web site: www.kramerelectronics.com, where updates to this user manual may be found. We welcome your questions, comments and feedback. Safety Warning: Disconnect the unit from the power supply before opening/servicing.