4. Gas supply pipe must not be more than 10" (25.4 cm) above
the floor.
A
/
/
B
D
A. Gas pressure regulator
B. Adapter
C. Flexible connector
D. Manual shutoff valve
E. 10" (25.4 cm) max. straight pipe
Complete
Connection
1. Open the manual shutoff valve in the gas supply line. The
valve is open when the handle is parallel to the gas pipe.
1.
2.
3.
4.
1.
2.
Move range close to cabinet opening.
Remove cardboard or hardboard from under the range. Using
2 or more people, gently move range into its final position.
Pull storage drawer out completely.
To check that the anti-tip bracket is installed, use a flashlight
and look underneath the bottom of the range.
Look for the anti-tip bracket securely attached to floor or
wall.
Slide range back so rear range foot is under anti-tip
bracket.
Place rack in oven.
Place level on rack and check levelness of range, first side to
side; then front to back.
2.
3.
A. Closed valve
B. Open valve
Test all connections by brushing on an approved noncorrosive
leak-detection
solution. If bubbles appear, a leak is indicated.
Correct any leak found.
Remove cooktop burner caps and grates from parts package.
Align recess in burner caps with pins in burner base. Burner
caps should be level when properly positioned. If burner caps
are not properly positioned, surface burners will not light.
Place burner grates over burners and caps.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension
cord.
Failure to folow
these instructions can result in death,
fire, or electrical
shock.
4. Plug into a grounded 3 prong outlet.
3. If range is not level, pull range forward until rear leveling leg is
removed from the anti-tip bracket.
4. Use wrench to adjust leveling legs up or down until range is
level. Push range back into position.
5. Check that rear leveling leg is engaged in anti-tip bracket.
NOTE: Range must be level for satisfactory
baking performance.
E _ _
_=_
Initial lighting and gas flame adjustments
Cooktop and oven burners use pilotless igniters in place of
standing pilots. When the cooktop control knob is turned to the
"LIGHT" position, the system creates a spark to light the burner.
This sparking continues, as long as the control knob is turned to
"LIGHT."
When the oven control is turned to the desired setting, a glow bar
igniter heats and ignites the gas.
Check Operation of Cooktop Burners
Standard Surface
Burners
Push in and turn each control knob to the "LIGHT" position.
The flame should light within 4 seconds. The first time a burner is
lit it may take longer than 4 seconds to light because of air in the
gas line.
If burners
do not light properly:
Turn cooktop control knob to the "OFF" position.
Check that the range is plugged in and the circuit breaker has
not tripped or the household fuse has not blown.