How to Convert
the Range for use
with LP/Propane
Gas
1. Convert
the
Pressure
Regulator
To access the regulator, remove
the kick panel, storage
drawer
or warmer
drawer.
If equipped
with a broiler
drawer,
open drawer
completely.
For models
equipped
with
warmer
drawer,
follow
the instructions
below
to
remove warmer
drawer.
a.
_
Electrical Shock Hazard can occur and
result in serious injury or death.
Disconnect electrical
power
to
the range
before
removing
the warmer
drawer for servicing.
b.
Open the drawer to the fully opened position.
c.
Locate glide lever on each side ofdrawer,
pull up on the
left glide lever and push down on the right glide lever
(see figure 1).
d.
Pull the drawer
away from the range.
Pull up with finger
LL_
Front Access
to Regulator:
Remove Kick Panel,
StorageDrawer,
or
Warmer Drawer.
(See Owner's Guide
for Instructions).
If Equipped with
Broiler Drawer,
n Broiler Drawer.
Pressure
Regulator
location at
rear of
range
Left Glide
Push down with finger
FIGURE 2
e.
Do not remove the Pressure Regulator
or allow it to
rotate
or turn.
Remove the dust protector from the
cap.
Using a 5/8" wrench,
unscrew
the cap from the
pressure
regulator.
Do not remove
the spring from
the regulator.
Do not pull on spring.
f.
Turn the cap over so the hollow
end faces outward.
Place the solid end of the cap into the loop end of the
dust protector
as shown
in illustration
below.
g.
Replace the cap on the regulator.
The letters LP should
be visible on the exposed end of the cap. Snap the dust
Right Glide
]
Lever
[]
FIGURE 1
protector
over the regulator
cap.
Dust
Protector
Hollow End
Solid End
Towards
Towards
Regulator
Regulator
for Natural Gas
for LP/Propane Gas
FIGURE 3