Direct
Electrical
Connection
to the Circuit
Breaker,
Fuse Box or Junction Box
If the appliance
is connected
directly
to the circuit
breaker,
fuse box or junction
box, use flexible,
armored
or nonmetallic
sheathed
copper
cable
(with grounding
wire). Supply a U.L. listed strain-
relief at each end of the cable.
At the appliance
end, the cable goes through
the Direct Connection
Hate (see Figure 9) on the Cord Mounting
Plate.
Wire
sizes (copper
wire only) and connections
must conform
to the rating
of the appliance.
Where local codes permit connecting the
appllance-grounding
conductor to the neutral
(white)
wire (see Figure 10):
1. Be sure that no power is supplied
on the cable
from residence.
2. Follow instructions
on previous
page for Four
Conductor
Wire
Connection
to Range (Fig. 9).
3. In the circuit breaker, fuse box or junction
box
(Fig. 10):
a) Connect
the green (or bare copper)
wire,
the white appliance
cable wire, and the neutral
(white) wire together.
b) Connect
the 2 black wires together.
c) Connect
the 2 red wires together.
Cable from Residence
i
Neutral
_'_
f
.Black
(white) Wire_[_
_
Wires-
Red
i
I
?rein
_ _White
Wire
tar
are
/
_
U L-listed Conduit
Conner)
Wire_"
'_
" "
_
Connector (or CSA
Cable from
listed)
Appliance
NOTE:
Be sure to remove
the
supplied
grounding
strap.
Figure 10
3-Wire
(Grounded
Neutral)
Electrical System
(Example:
Junction
Box)
Where local codes DO NOT permit connecting
the appllance-grounding
conductor to the neutral
(white)
wire, or if connecting to 4-wlre
electrical
system
(see Figure 11):
1. Be sure that no power
is supplied
on the cable
from residence.
2. Follow instructions
on previous
page for Four
Conductor
Wire Connection
to Range (Fig. 9).
3. In the circuit
breaker, fuse box or junction
box
(Fig. 11):
a)Connect
the white appliance
cable
wire to the
neutral
(white) wire.
b) Connect
the 2 black wires together.
c) Connect
the 2 red wires together.
d) Connect
the green (or bare copper)
grounding
wire to the grounding
wire of the circuit
breaker,
fuse box or junction
box.
Cable from
Green (or Bare
Residence
Copper) Wir
Red
7
Junction
Box
White
ire
rC_!ire
....
_--U
.L.-listed Conduit
Connector
(or CSA
listed)
Cable from
Appliance
NOTE:
Be sure to remove
the
supplied
grounding
strap.
Figure 11
4-Wire
Electrlcal System (Example:
Junction
Box)
6. Checking
Operation
Refer to the Use and Care Gulde for operation.
_Do
not touch cooktop
glass or
elements.
They may be hot enough to burn you.
Before
You Call for Service
Read the Before You Calt for Service Checklist
and operating
instructions
in your Use and Care
Guide.
It may save you time and expense.
The
list includes common
occurrences
that are not the
result of defective
workmanship
or materials
in this
appliance.
Refer to your Use and Care Guide for Sears service
phone numbers, or call 1-800-4-MY-HOME
®.
6

Advertisement

Table of Contents
loading

Table of Contents