Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
120-Volt, 60-Hz., AC-only, 15- or 2g-amp fused electrical
supply is required. (Time-delay fuse or circuit breaker is
recommended.)
It is recommended
that a separate circuit
serving only this dryer be provided.
IMPORTANT: The dryer must be electrically grounded in
accordance with local codes, or in the absence of local codes,
with the National Electrical Code, ANSI/NFPA 70.
GROUNDING
INSTRUCTIONS
• For a grounded, cord-connected
dryer:
This dryer must be grounded. In the event of malfunction or
breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for electric current.
This dryer is equipped with a cord having an equipment-
grounding conductor and a grounding plug. The plug must
be plugged into an appropriate outlet that is properly
installed and grounded in accordance with all local codes
and ordinances.
WARNING:
Improper connection of the equipment-
grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or service representative
or personnel if you are in doubt as to whether the dryer is
properly grounded. De not modify the plug provided with the
dryer: if it will not fit the outlet, have a proper outlet installed
by a qualified electrician.
SAVE THESE
INSTRUCTIONS
Explosion Hazard
Use a new AGA or CSA approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure
gas pressure does not exceed 13" (33 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel,
and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
Gas Type
Natural Gas:
This dryer is equipped for use with natural gas. It is design-
certified by CSA International for L.R (propane or butane) gases
with appropriate
conversion.
Your dryer must have the correct burner for the type of gas in
your home. Burner information
is located on the rating plate
in the door well of your dryer. If this information
does not
agree with the type of gas available, contact your local Sears
store or Sears Service Center.
L.P. gas conversion:
Conversion
must be made by a qualified
technician.
No attempt shall be made to convert the appliance from the gas
specified on the model/serial
rating plate for use with a different
gas without consulting the serving gas supplier.
IMPORTANT: The gas installation must conform with local
codes, or in the absence of local codes, with the National Fuel
Gas Code, ANSI Z223.1/NFPA
54.