CROWN VERITY MCB30 Owner's Manual

CROWN VERITY MCB30 Owner's Manual

Crown verity grill
Hide thumbs Also See for MCB30:

Advertisement

MODELS: MCB30, MCB36, MCB48, MCB60 & MCB72
CONGRATULATIONS! You are the proud new owner of the finest commercial mobile
charbroiler available. CROWN VERITY Inc. charbroilers are designed to last a
lifetime...or more! With proper care and maintenance, your charbroiler will provide
unparalleled performance and countless years of outdoor cooking.
Please read this manual carefully to ensure safe operation and to maximize your
cooking enjoyment. It is your responsibility to see that your grill is properly assembled,
installed, and cared for. Failure to follow instructions in this manual could result in
serious bodily harm and/or property damage.
WARNING: Improper installation, adjustment, alteration, service or
maintenance can cause property damage, injury or death. Read the
installation, operating and maintenance instructions thoroughly before
installing or servicing this equipment.
CROWN VERITY INC., 37 ADAMS BLVD., BRANTFORD, ON. CAN. N3S 7V8
OWNER'S MANUAL
REVISED MARCH, 2001
*PLEASE RETAIN FOR FUTURE REFERENCE
TEL: (519) 751-1800
www.crownverity.com
Email: info@crownverity.com
FAX: (519) 751-1802

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MCB30 and is the answer not in the manual?

Questions and answers

Summary of Contents for CROWN VERITY MCB30

  • Page 1 *PLEASE RETAIN FOR FUTURE REFERENCE CONGRATULATIONS! You are the proud new owner of the finest commercial mobile charbroiler available. CROWN VERITY Inc. charbroilers are designed to last a lifetime...or more! With proper care and maintenance, your charbroiler will provide unparalleled performance and countless years of outdoor cooking.
  • Page 2: Table Of Contents

    Parts and Components ........17 CROWN VERITY INC., 37 ADAMS BLVD., BRANTFORD, ON. CAN. N3S 7V8...
  • Page 3 FOR YOUR SAFETY IF YOU SMELL GAS: 1) Shut off gas supply to appliance. 2) Extinguish any open flame. 3) Open lid or remove storage cover(s). 4) If odour continues, immediately call your gas supplier. DO NOT store or use gasoline or other flammable vapours and liquids in the vicinity of this or any other appliance.
  • Page 4: Installing Your Mobile Charbroiler

    1/2 psi. (3.45kPa). CROWN VERITY INC., 37 ADAMS BLVD., BRANTFORD, ON. CAN. N3S 7V8 TEL: (519) 751-1800 FAX: (519) 751-1802 www.crownverity.com...
  • Page 5 FIG 1 CLEARANCES TO COMBUSTIBLES 24” 12” 12” FIG 2 BURNER ASSEMBLY DETAIL VENTURI AIR INLET 5/16” x 5/8” APPROX SCREW 1/2” BURNER VALVE CROSS-OVER ORIFICE BURNER AIR SHUTTER...
  • Page 6: Storing Your Mobile Charbroiler

    Install plastic caps to quick connect fittings. The charbroiler may then be stored indoors or outdoors. For long term storage, follow the storage instructions above. CROWN VERITY INC., 37 ADAMS BLVD., BRANTFORD, ON. CAN. N3S 7V8 TEL: (519) 751-1800 FAX: (519) 751-1802 www.crownverity.com...
  • Page 7: Cylinders And Regulators

    CYLINDERS AND REGULATORS LP GAS CYLINDER: - self-contained Propane Gas System The self-contained propane system charbroiler is designed for use with a 9.1 kg. (20 lb.) propane cylinder, equipped with a Type I cylinder valve. This charbroiler cannot be connected to a standard Type II valve (with internal left-hand threads only). DO NOT CONNECT TO A PROPANE GAS CYLINDER EXCEEDING THIS CAPACITY, OR USE A CYLINDER WITH ANY OTHER TYPE OF VALVE.
  • Page 8: Hoses And Regulators

    TRANSPORTATION AND STORAGE OF LP CYLINDERS Although safe to use when properly handled, careless handling of a propane gas cylinder could result in fire, explosion, and/or serious injury. THEREFORE: Always use the protective cap provided with your cylinder whenever it is not connected to your charbroiler.
  • Page 9 NATURAL GAS AND FIXED LP MODELS: RE: HOSES Crown Verity Inc. charbroilers that are equipped for use with natural gas or fixed LP systems require care and attention to the hose. • Inspect the hose, clean quick-connect coupling, and keep protected.
  • Page 10: Leak Testing

    (see fig. 2, pg.3). Ensure venturi tubes are properly “seated” over the orifices. CROWN VERITY INC., 37 ADAMS BLVD., BRANTFORD, ON. CAN. N3S 7V8 TEL: (519) 751-1800 FAX: (519) 751-1802 www.crownverity.com...
  • Page 11: Prior To Use And Lighting Instructions

    PRIOR TO USE AND LIGHTING INSTRUCTIONS WARNING! Do not use your charbroiler until you have read and understood all the information in this manual, and you are assured: • There are no leaks in the gas supply system (see “Leak Testing” section). •...
  • Page 12: Operating And Shut Down Instructions

    4) Close lid(s) or install protective cover(s) until future use. 5) Disconnect LP cylinder(s) from the charbroiler when not in use. 6) Take care; your charbroiler is still hot. CROWN VERITY INC., 37 ADAMS BLVD., BRANTFORD, ON. CAN. N3S 7V8 TEL: (519) 751-1800 FAX: (519) 751-1802 www.crownverity.com...
  • Page 13: Tips And Techniques

    COOKING TECHNIQUES: There are several ways to cook on your Crown Verity Inc. charbroiler, here are but a few: Lid Up or Lid Down Although keeping the lid up or down when grilling directly on the grids is a matter of personal choice, you’ll find your charbroiler will keep a more constant temperature, and...
  • Page 14: Cleaning And Maintenance

    CLEANING AND MAINTENANCE All Crown Verity Inc. charbroilers are easily cleaned because of their stainless steel construction. For minor clean-ups, we suggest a general-purpose mild cleansing formula. For heavy grease build-up, apply an oven cleaner to stainless steel surfaces only, following the manufacturer’s instructions.
  • Page 15: Troubleshooting Guide

    TROUBLESHOOTING GUIDE WHAT HAPPENS WHAT TO LOOK FOR Out of propane? Improper lighting procedures? Is 1) Burners will not light cylinder valve turned on? Regulator assembly not fully tightened to cylinder valve? Gas piping system is full of air - Bleed out system, wait five minutes and repeat lighting procedures.
  • Page 16: Conversion

    The manufacturer supplies all conversion equipment kits. Note: To order conversion kit(s), call Crown Verity Inc. at (519) 751-1800, or fax (519) 751-1802. Technical help is available during most weekday business hours. When ordering your conversion kit(s), please state the type of gas to be used and the model number of your charbroiler.
  • Page 17 MANIFOLD COUPLING PIPE DETAIL SEE TABLE 3/4" NPT SHORT 3/4" SCH. 3/4" NPS. 40 NIPPLE SCH. 40 GAS PIPE 3/4" UNION MCB 60 AND MCB 72 MANIFOLD COUPLING PIPE MANIFOLD COUPLING PIPE 3/4" TEE 90° ELBOW NIPPLE 3/4" NPS. GAS PIPE 3/4"...
  • Page 18: Frequently Asked Questions About Mcb's

    Using this formula, With a twenty pound cylinder (full) and using the average maximum input (amount of gas used) for MCB’s. We came up with an average cylinder life of 3 to 3-1/2 hrs. CROWN VERITY INC., 37 ADAMS BLVD., BRANTFORD, ON. CAN. N3S 7V8 TEL: (519) 751-1800 FAX: (519) 751-1802 www.crownverity.com...
  • Page 19: Parts And Components

    The drawing is the property of Crown * Note: Please specify model number, 53 2205 Roll Dome Pivot Assembly improvement Crown Verity Inc. reserves Verity Inc. and it is not to be reproduced type of gas and serial number when...
  • Page 20 CROWN VERITY INC., 37 ADAMS BLVD., BRANTFORD, ON. CAN. N3S 7V8 TEL: (519) 751-1800 FAX: (519) 751-1802 www.crownverity.com Email: info@crownverity.com...

This manual is also suitable for:

Mcb36Mcb60Mcb48Mcb72

Table of Contents