Safety Precautions

The breaker of the air conditioner should be all-pole switch; and
the distance between its two contacts should be no less 3mm. Such means for
disconnection must be incorporation in the fixed wiring.
Use copper wire only. All the cables shall have got the European authentication certificate.
For these units, the power supply connects from the outdoor side. The connecting
cable are self-provided.
The parameter of connecting cable:
The requirement of the cross section area of the power supply cord:
3N~,380-400V, 50Hz, H07RN-F 5G 2.5mm
Do not attempt to install this air conditioner by yourself.
This unit contains no user-serviceable parts. Always consult authorized service personnel
for repairs.
When moving, consult authorized service personnel for disconnection and installation of
the unit.
Do not become excessively chilled by staying for lengthy periods in the direct cooling
airflow.
Do not insert fingers or objects into the outlet port or intake grills.
Do not start and stop air conditioner operation by connecting and disconnecting the
power supply cord and so on.
Take care not to damage the power supply cord. If the supply card is danaged, it must be
replaied by the manufacturer or authoried service agent in order to avoid a hazard.
In the event of a malfunction (burning smell, etc.), stop operation immediately, turn off
the circuit breaker, and consult authorized service personnel.
WARNING!
HCFU-42CF03 4G 1.0mm
.
2
DANGER!
3
, HCFU-42HF03 6G 1.0mm
2
.
2