Haier HC18D2VAR Installation & Operation Manual

13 seer 1.5 to 3.5 ton central air conditioner
Hide thumbs Also See for HC18D2VAR:

Advertisement

Central Air Conditioner
13 SEER 1.5 to 3.5 Ton
Models: HC18D2VAR
HC24D2VAR
HC36D2VAR
HC30D2VAR
HC42D2VAR
No.0010578572
The information contained in this booklet is subject to change without notice.

Advertisement

Table of Contents
loading

Summary of Contents for Haier HC18D2VAR

  • Page 1 Central Air Conditioner 13 SEER 1.5 to 3.5 Ton Models: HC18D2VAR HC24D2VAR HC36D2VAR HC30D2VAR HC42D2VAR No.0010578572 The information contained in this booklet is subject to change without notice.
  • Page 2 (other than those authorized by the manufacturer) into, onto, or in conjunction with the air conditioner. You should be aware that the use of unauthorized components, accessories or devices may adversely affect the operation of the air conditioner and may also endanger life and property.
  • Page 3: Table Of Contents

    9.3.Wiring diagram ----------------------------------------------------------------------------- 1.INTRODUCTION This manual contains the installation and operating instructions for your new air conditioner. Improper installation can result in unsatisfactory operation or dangerous conditions. Carefully read this manual and any instructions packaged with separate equipment required to make up the system prior to installation.
  • Page 4: Specification

    Net Dimensions - In (mm) W*D*H Shipping Dimensions - In (mm) W*D*H Net Weight - Lbs (kg) Approx Shipping Weight - Lbs (kg) Table 2:System Cooling Capacity Cooling Outdoor Indoor HC18D2VAR HB2400VD1M20 HC24D2VAR HB2400VD1M20 HC30D2VAR HB3600VD1M22 HC36D2VAR HB3600VD1M22 HC42D2VAR HB4800VD1M22...
  • Page 5 Figure 2 Central Air Conditioner Refrigerant Circuit SERVICE PORT SERVICE VALVE COMPRESSOR SERVICE PORT DRIER(optional) INDOOR COIL OUTDOOR COIL SERVICE VALVE DISTRIBUTOR !Warning - The drier is strongly recommended to be installed by installer and replaced once two years. This will give your equipment great help in long life.
  • Page 6: Unit Inspection

    4.UNIT INSPECTION This product has been inspected at the factory and released to the transportation agency without known damage. Inspect exterior of carton for evidence of rough handling in shipment. Unpack carefully. If damage is found, report immediately to the transportation agency. 5.EQUIPMENT PROTECTION FROM ENVIRONMENT The metal parts of the unit may be subject to rust or corrosion in adverse environmental conditions.
  • Page 7: Unit Clearances

    Provide a level concrete slab. To prevent transmission of noise or vibration, slab should not be connected to building structure. Some sort of sound-absorbing material should be placed between the condenser and the slab. A good material to use is rubber and cork pad. For rooftop application, make sure the building construction can support the weight and that proper consideration is given to the weather-tight integrity of the roof.
  • Page 8: Line Insulation

    PITCH SUCTION LINE TOWARD OUTDOOR UNIT 1/2" FRO EVERY 10' OF LINE OUTDOOR UNIT LIQUID LINE INVERTED LOOP LIQUID LINE INDOOR UNIT OUTDOOR UNIT SUCTION LINE Only refrigeration-grade copper piping (dehydrated and sealed) should be used. Take extreme care to keep the refrigerant tubing clean and dry prior to and during installation.
  • Page 9 Refrigerant Line Sizing Check the following table (Table 3) for correct suction and liquid line sizes for any combination of the unit size and the maximum refrigerant line length. Unit Size 0 - 24 (Ton) Suction The factory charge is sufficient for 25 feet of standard liquid line. For longer or shorter liquid line lengths, adjust the charge as follows: 1/4"...
  • Page 10 Refrigerant Metering Devices Replace the existing indoor unit fixed orifice with the orifice supplied with the outdoor unit. See table 4 for the fixed orifice size for each unit. Table 4 outdoor model HC18D2VAR HC24D2VAR HC30D2VAR HC36D2VAR HC42D2VAR Fixed orifice size...
  • Page 11 Evacuation All new installations must be evacuated to a deep vacuum in order that all noncondensible gases and moisture are removed prior to charging the system. Air in a system causes high condensing pressure, which increases power consumption and reduces performance. The presence of moisture in a system can render it inoperable in a very short time.
  • Page 12: Electrical Wiring

    1.Fully open both shutoff valves. 2.Connect service gage manifold to the valve service ports, being sure to evacuate lines. 3.Startup the system (Refer to the Section 7 - "System Startup"). Run system at least 10 minutes to allo pressure to stabilize. 4.Temporarily install thermometer on suction (large) line near condensing unit.
  • Page 13: System Startup

    The condensing unit rating plate and the tables of "Physical and Electrical Specifications / Outdoor Units" (Table 1 and 2) provide pertinent data necessary for the selection of proper size electrical service and over-current protection devices. Table 6 provides data on the minimum copper wire size as a function of supply wire length and circuit ampacity.
  • Page 14: Operation

    8.OPERATION Most single phase units are operated without start relay or start capacitor. Such systems should be off for a minimum of 5 minutes before restarting to allow equalization of pressures. The thermostat should not be moved to cycle unit without waiting 5 minutes. To do so may cause the compressor to stop on an automatic open overload device or blow a fuse.
  • Page 15 Symptom Possible Cause Power off or loose electrical connection Incorrect thermostat setting No cooling Defective contactor Open circuit breaker of blown fuses Defective transformer Interconnecting low voltage wiring damage Replace thermostat wiring Dirty filters Indoor air blockage Blocked outdoor coil Improperly sized unit Insufficient Cooling Improper airflow Incorrect refrigerant charge...
  • Page 16 HC18-42D2VAR Air Conditioner Wiri ng Diagram YL/GR 208/230V 60Hz 1PH Compress or Prot ect 3 Min. Time Delay Opt ion al Low & High Pressur e Switches COMPRESSOR 24VAC COMMON 1) Confirm system selection. Optional components may be field or factory installed.
  • Page 17 Made in P.R.C.

This manual is also suitable for:

Hc42d2varHc24d2varHc30d2varHc36d2var