Hafler P3000 Installation And Operation Manual

Hafler P3000 Installation And Operation Manual

2-channel audio power amplifier/speaker
Hide thumbs Also See for P3000:

Advertisement

P1500 / P3000
Installation & Operation
PROFESSIONAL POWER AMPL
PROFESSIONAL POWER AMPLIFIER
®

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the P3000 and is the answer not in the manual?

Questions and answers

Summary of Contents for Hafler P3000

  • Page 1 P1500 / P3000 Installation & Operation PROFESSIONAL POWER AMPLIFIER PROFESSIONAL POWER AMPL ®...
  • Page 2: Declaration Of Conformity

    Declaration of Conformity Application of Council Directive: 73 / 23 / EEC (Low Voltage Directive) Standard(s) to which Conformity is Declared: EN55103-1 Manufacturer’s Name: Hafler Manufacturer’s Address: 546 South Rockford Drive, Tempe, Arizona 85281 Importer’s Name: Importer’s Address: Type of Equipment: 2-channel Audio Power Amplifier/Speaker Model No.: P1000CE...
  • Page 3: Specifications

    E R F O R M A N C E P1500/P3000 Frequency Response: 20Hz to 20kHz, 0.1dB 0.15Hz to 300kHz, +0/–3dB Signal-to-Noise: >100dB “A” Weighted Distortion: <0.2% 20-20kHz, typically .01% at 1kHz @ rated power into 8 Slew Rate: 100 V/ s...
  • Page 4 HAZARD, DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE. READ INSTRUCTIONS All the safety and operating instructions of your Hafler equipment should be read before power is applied to the equipment. RETAIN OWNER'S MANUAL These safety and operating instructions should be retained for future reference.
  • Page 5 LEA LAS INSTRUCCIONES Todas las instrucciones de seguidad y operación de su equipo Hafler, deben ser leídas antes de que el equipo sea conectado dléctricamente. CONSERVE EL MANUAL DEL PROPIETARIO Estas instrucciones de seguridad y operación, deben ser conservadas...
  • Page 6 à éviter toute pénetration dans l'enceinte du matériel. 14. DÉGÂT NÉCESSITANT UNE RÉVISION Le matériel Hafler devrait être révisé par des personnes qualifées de service après-vente, lorsque: A. Les fiches ou la prise de courant ont été endommagé, ou: B.
  • Page 7 Um die gefahr eines elektroschocks oder feuer zu vermeiden, setzen sie das gerät keinem regen oder extremer feuchtigkeitaus. INSTSRUKTIONEN LESEN Alle Sicherheits- und Operationshinweise Ihres Hafler Equipments sollten vor der Inbetriebnahme gelesen werden. BETRIEBSANLEITUNG AUFBEWAHREN Bewahren Sie die Bedienungsanleitung sorgfältig auf, damit Sie in dieser auch in Zukunft nachschlagen können.
  • Page 8 Si deve prestar attenzione che oggetti e liquidi, come fluidi detergenti e bibite, non vengano versati all'interno dell'apparato. 14. RIPARAZIONI Gli apparati Hafler devono essere riparati da personale qualificato quando: A. Il cavo di alimentazione o la spina sono danneggiati B.
  • Page 9: Table Of Contents

    A B L E O F PERFORMANCE SPECIFICATIONS ... i SAFETY PRECAUTIONS ... ii INTRODUCTION ... 1 FRONT & REAR PANEL VIEW ... 2 INSTALLATION Location ... 3 AC Line ... 3 Input ... 4 PC Board Layout ...Removable Center Spread Output Connections ...
  • Page 10: Introduction

    This manual contains information on using the P1500 and P3000 amplifiers. It is organized into three main sections. “Installation” covers the location and connection of the amplifier in the system. Like many precision components careful attention to the initial setup can yield dividends in higher performance and trouble-free use.
  • Page 11: Front & Rear Panel View

    – 2 –...
  • Page 12: Installation

    N S T A L L A T I O N LOCATION The P1500 and P3000 power transformer can generate a substantial magnetic field, so caution should be exercised in the placement of low level components such as a tape deck, mixer or mic preamp to avoid inducing noise in the low level circuitry.
  • Page 13: Input

    Pin 2 = (+) Pin 3 = (–) Many popular mixers use unbalanced outputs and can be used with the Hafler amplifier. To minimize residual ground noise, we recommend using twisted pair cable or short cable lengths in this type of configuration.
  • Page 14 C H E M A T I C I A G R A M P3000 shown. Ground switch in Chassis position, Mono switch in 2-Channel position. P1500 differences shown on parts list. Removable Center Spread...
  • Page 15 Removable Center Spread...
  • Page 16: Output Connections

    OUTPUT CONNECTIONS The speaker output connectors are dual binding posts. These binding posts will directly accept 12 AWG wire or banana plugs and are spaced on 3/4" centers to accept dual banana plugs. MONOPHONIC USE For systems with high power requirements, the amplifiers can be configured for single channel bridged mono operation.
  • Page 17: Short Circuit Protection

    SHORT CIRCUIT PROTECTION Due to the self-protecting properties of the output power MOSFETs, there is no need for sonically degrading voltage and current limiting circuits. To protect the amplifier from problems which may occur in the speaker line there is an overload detection circuit. In the event of a short in the speaker load or cables, the speaker detection circuit will shut down that channel and light the front panel SHORT indicator.
  • Page 18: Pc Board Layout

    C121 R165 ROCKFORD CORP PC-0812-H R132 R138 M.ALBERS R134 R131 R133 R141 CR11 C115 C114 R139 R129 C113 R124 Q105 Q103 R128 Q104 R123 ARTWORK COMPONENT SIDE C122 Z2 Z3 Z 1 X4 X3 Q116 C123 R164 C126 C116 CR15 R140 R136 CR14...
  • Page 19: Parts List

    A R T S I S T P3000U 120VAC, 60Hz DESIGNATOR VALUE ALL RESISTORS IN OHMS, 1/4W 56.2k 4.7k 1.07k 200, Trim Pot 470k 3.3M 4.7k 100k 604k 45.3k 2.2M 100k 100k 10k Pot 2.2M 3.92k 3.92k 3.3M 6.8k 4.7k 4.7k PART # RMP/4-5622...
  • Page 20 LM339 Comparator SS-730SM Power Switch SWH-1009 IEC Connector CC-0852 IEC Line Cord FAH-146 Dual Binding Post CC-0867 P3000 Transformer TT-1531 Fuse, 1A Fast FS-1592 Fuse, 1A Fast PS-1592 Fuse, 5A Slo Blo FS-005SB European Linecord FA-1464 Fuseholder Cup 5x20mm FS-1125 1.25A Slo Blo 5x20mm FS-1474A...
  • Page 21: Technical Reference

    FIELD SERVICE CONSIDERATIONS A primary focus during the design and development of the P1500 and P3000 was to ensure the dependability of the amplifiers. The use of lateral MOSFET output transistors and the low voltage trans• nova input stage combined with careful component selection for the circuit assembly made the reliability goals achievable.
  • Page 22: Circuit Operation

    CIRCUIT OPERATION trans• nova Implementation: +18V Positive Buffer, DC Positive Input Offset Integrator Buffer U2A, R11, C21, Level Adjust Balanced Signal R24 A, B Negative Input Negative Buffer Buffer Protection Switch, Soft Start Delay –18V The transistor Q1 is configured to operate as a switch which controls the current source, Q103, of the input differential amp, Q6 and Q7.
  • Page 23: Output Short Protection

    Output Short Protection Drive Signal Output Signal The Short detector monitors the Drive Signal and Output Signal levels and shuts down that channel when a shorted output condition is detected. Recovering from the Short protection requires turning the amplifier off to reset. The comparator U4B monitors the Drive Signal and goes low when the drive level is sufficient to clip the output stage.
  • Page 24: Clipping Indicator

    To adjust the bias, disconnect the input and speakers and remove the jumper JW7. Connect an amp meter across the exposed pins. Adjust R136 to get a current reading of 100 mA for the P1500, 200 mA for the P3000. WARNING: Only a competent technician should attempt the following procedure.
  • Page 25: Module Replacement

    amplifier. For a temporary adjustment when a signal generator and voltmeter are not available, use an FM tuner and tune it to an unused station as your signal source, and connect the output to the amplifier as described above. Connect the amplifier output to a small full range speaker.
  • Page 26: Warranty

    Some states do not allow limitations on the length of an implied warranty, so this limitation may not apply. No person is authorized to assume for Hafler any other liability in connection with the sale of the product.
  • Page 27 OTES...
  • Page 28 ® HAFLER A DIVISION OF ROCKFORD CORPROATION 546 SOUTH ROCKFORD DRIVE TEMPE, ARIZONA 85281 U.S.A. 480-967-3565 / 1-888-HAFLER1 WWW.HAFLER.COM MAN-1461-C 4/99 E.W.R.

This manual is also suitable for:

P1500

Table of Contents

Save PDF