Download Print this page

Specifications - Tripp Lite EMS1012UL Features & Specifications

Powerverter ems inverter/charger - reliable mobile power source for ambulance/ems vehicles

Advertisement

Advanced 15/55 amp selectable, 3-stage battery charger and selector switch for gel or wet cell batteries
Switch allows user to select between off, auto-invert and charge-only settings
6 diagnostic LEDs indicate AC present, on battery, overload, & battery voltage level (high, medium, & low)
Configuration switches to allow the user to select the high and low voltage for the unit to automatically transfer from AC power to battery
backup
Coated internal circuit boards offer continuous operation in humid environments (0-95%, non condensing)
RJ45 port allows connection of remote switch (part# External switch for wired remote control of APS unit (APSRM4) which is included
Included remote switch can be linked in a daisychain with a second remote switch (sold separately) for remote operation from multiple
locations. Multiple mounting options include recess panel mount or below dash.Ignition interlock feature can shut down unit when engine is
off, ending worries of accidental battery drain
Allows unlimited runtime capability by allowing the use of any number of user-supplied batteries

Specifications

OUTPUT
Frequency
60 Hz
compatibility
Output watts
Continuous - 1000 watts, Overpower (up to 1 hour) - 1500 watts, Double-Boost wattage (up to 10 seconds) - 2000 watts
Output nominal
AC OUTPUT: 120VAC nominal, DC CHARGER OUTPUT (DC): 12VDC nominal
voltage
Output voltage
LINE POWER (AC): Maintains 120V nominal sine wave output. INVERTER POWER (AC): Maintains PWM sine wave
regulation
output voltage of 120 VAC (+/-5%). DC CHARGER OUTPUT (See battery recharge rate section)
Output frequency
60 Hz (+/- 0.3 Hz)
regulation
Overload
Includes 12A input breaker dedicated to the charging system and 12A output breaker for AC output loads
protection
Outlet quantity /
Includes 2 hospital-grade AC outlets with built-in GFI protection (NEMA 5-15R)
type
INPUT
Recommended
DC INPUT: Requires 12VDC input source capable of delivering 95A for the required duration (when used at full
Electrical Service
continuous capacity). For automotive applications, professional hardwire installation with 225A minimum battery system
fusing is recommended. A
Maximum input
DC INPUT: Full continuous load - 95A at 12VDC. AC INPUT: 12 amps at 120VAC with full inverter and charger load
amps / watts
Input connection
DC INPUT: 175A Anderson DC connector. AC INPUT: NEMA 5-15P hospital-grade input plug
type
Voltage
120
compatibility
(VAC)
Voltage
12
compatibility
(VDC)
BATTERY
Expandable
Runtime is expandable with any number of user supplied wet or gel type batteries
battery runtime
DC system
15
voltage (VDC)
Battery charge
Includes selectable 14 / 55 amp DC charging system with selectable profiles for vented wet cell and sealed gel cell
batteries. Optional use battery equalize charge function equalizes the charge level when used with multiple batteries
(see manual for detailed charger information).
LEDS ALARMS & SWITCHES

Advertisement

loading