INSTALLATION AND OPERATING MANUAL 50W Ku-BAND HUB-MOUNT SOLID STATE POWER AMPLIFIER AWSA-K50-CHE PM 100-432350-530, REV. 1...
Page 2
LIMITATIONS OF WARRANTY ADVANTECH Advanced Microwave Technologies, Inc. warrants this product to be free of materials and workmanship defects. The foregoing warranty shall not apply to defects resulting from improper handling or abuse by the Buyer, unauthorized modification, operation outside of the environmental specifications for the product, or improper installation or maintenance.
AWSA-K50-CHE 2. SAFETY In addition to this section, included by reference are the following pertinent sections of the International Standard IEC-215, ‘Safety requirements for radio transmitting equipment’: - Appendix D, ‘GUIDANCE ON ASSESSING THE COMPETENCE OF PERSONNEL FOR DESIGNATION AS SKILLED’ and also Sub-clause 3.1 of the Standard.
Page 8
AWSA-K50-CHE ---------------------------------------------- WARNING ----------------------------------------------------- When supplying power to this equipment, connect the accessory 3-pin power connector (with extension cable) to a 3-pin grounded power outlet. If power is supplied without grounding the equipment, there is a risk of receiving a severe or fatal electric shock.
50W Ku-band hub-mount (Outdoor) Solid State Power Amplifier Model # AWSA-K50-CHE. Because specialized training is required for some phases of installation and operation, certain parts of this manual are directed only to trained personnel. Warnings appear at the appropriate points to caution all users of potential RF and high-voltage hazards.
AWSA-K50-CHE 3.1 E LECTRICAL PECIFICATIONS The SSPA specified herein is capable of meeting or exceeding the performance specifications listed in the following table over frequency range, operating temperature and line voltage variation unless otherwise specified. The SSPA will meet all RF performance specifications within thirty minutes of application of prime power.
Page 11
AWSA-K50-CHE ELECTRICAL SPECIFICATIONS (continued) 1.3:1, max (RL = 17.7 dB) Unconditionally stable over the frequency and ambient VSWR Input/Output operating temperature range, with no damage to the SSPA under any load or source condition RF Input Connector N-Type Female WR-75G, supplied with waterproof gasket Waveguide Flange Output Connector - 60 dBc, max, 13.750 –...
AWSA-K50-CHE 4. MAJOR SUBSYSTEMS AND THEIR FUNCTIONS The AWSA-K50-CHE is a Ku-band 50W Solid State Power Amplifier (SSPA). The power amplifier is intended for mounting near the hub of the antenna. It incorporates DC main power supply and forced air cooling system, see Figure 1: Product Outline at page 11. The block diagram of the SSPA is shown in Figure 2 at page 13 and various connectors are shown in Figure 3 at page 14.
AWSA-K50-CHE MODEL BAND FREQUENCY RF OUTPUT POWER INPUT VOLTAGE min. GAIN INPUT CURRENT REV. Figure 3: Connectors TABLE 1: CONNECTORS Connector Function Description Mating Connector (J1) RF Input N-Type (F) N-Type (M) (J3) Discrete Interface MS3112E16-26P (M) MS3116F16-26S (F) (J4)
AWSA-K50-CHE 4.2 P OWER UPPLY UBSYSTEM The power supply portion of the SSPA provides all of the internal voltages necessary to operate the RF section and the Alarm/Indicate board. The power supply is configured for 90-132 or 180- 265 VAC input AC line (auto-ranging). The overall power consumption is 700W typical, at rated RF output power.
AWSA-K50-CHE 5. UNPACKING AND INSTALLATION This section contains instructions for site preparation, unpacking and installation of the SSPA. 5.1 I NITIAL NSPECTION Inspect the shipping container for damage. If the container or cushioning material is damaged, immediately contact the carrier that delivered the equipment and submit a damage report. Failure to do so could invalidate future claims.
AWSA-K50-CHE TABLE 3: MECHANICAL SPECIFICATIONS Physical Dimensions See Figure 1: Product Outline at page 11 Approximate Weight 30 lbs (14 kg) Mounting holes (6) 0.40” (10 mm) dia. See Figure 1: Product Outline at page 11 5.3.2 LECTRICAL ONNECTIONS For the locations of the connectors see Figure 1 at page 11 & Figure 3 at page 14. Electrical interconnections to the system consist of prime power (J5) and external connections for discrete interface (J3).
The center pin of the connectors used by ADVANTECH has a precision tolerance measured in mils (1/1000 inch). The mating connectors of various suppliers may not be precision types. Consequently, the center pins of these devices may not have the proper depth.
AWSA-K50-CHE 5.3.4 C OOLING ONSIDERATIONS The SSPA is cooled by forced air. The cooling fan is configured for 48V DC operation. Depending on environmental conditions, the air inlet or outlet openings may become obstructed by debris, reducing the efficiency of the cooling system. Inspect the unit periodically to ensure that the grill of the fan intake and all openings on the unit are free of any obstructions.
The SSPA is provided with interfaces that can be used to connect it with several optional external devices. The interfaces for this model (AWSA-K50-CHE) are listed bellow: 1. Discrete Interface (J3): This form-C relay remote interface offers essential SSPA monitoring (FAULT and thermal shutdown) via individual signals per SSPA status.
AWSA-K50-CHE 6.1.1 F UNCTIONAL ESCRIPTION The Discrete Interface is connected to the Alarm/Indicate Board and continuously (in the normal condition) monitors the status of the SSPA: • the power amplifier is ON • there are no problems in the power amplifier •...
AWSA-K50-CHE 7. INITIAL POWER ON AND CHECKOUT This section describes the procedure for turning on the SSPA for the first time. It also describes the steps for initial checkout of the system. Before proceeding with the steps in this section, read it completely, to become familiar with normal operation of the SSPA.
AWSA-K50-CHE 8. OPERATION This section describes the normal operation of the SSPA. The SSPA features an integrated Alarm/Indicate Board that accepts control input and provides SSPA status and metering. The design of this equipment allows minimum operator intervention and maintenance.
AWSA-K50-CHE 9. MAINTENANCE This section describes scheduled maintenance procedure for SSPA. CAUTION: Improper maintenance of the SSB may void the warranty. 9.1 P REVENTIVE AINTENANCE This product requires minimum maintenance. This consists of visual inspection and cleaning. WARNING: The person performing maintenance of this equipment must have training and knowledge of both the product and safety requirements and safety issues related to the equipment.
AWSA-K50-CHE 10. APPENDIX A: SAFETY AND EMC COMPLIANCE Advantech Products are compliant with following standards: SAFETY: IEC 950 (1992) CAN/CSA-C22.2 No. 950 –92/ UL 1950 EMC: EN 55022: 1995 / CISPR22:1993 – Class A Conducted and Radiated Emission. Conducted: 0.150-30 MHz, Radiated: 30-1000 MHz.