Standard Vertical Installation Configurations
Model: Montage™ 3FS
This free-standing model may be connected to an existing flue or by
installing listed type "PL" vent pipe. If a liner is run all the way to the
top of the existing chimney, the existing flue should be sealed with a
steel plate. Start a vertical run with a Tee at the back of the stove. Other
options are illustrated below.
Figure 18 - Exterior Vertical Vent
Optional Complete
Liner and Listed
Termination Cap
Maintain clearances
specified by vent
manufacturer
Figure 19 - Vertical Vent Into a Masonry Flue
16
Preferred Installation – Vertical Vent Through the Roof
This venting configuration allows for the best stove performance. The
vertical pipe promotes natural draft and with the chimney inside the
dwelling, the flue gases stay warm, thus rising at a consistent rate.
Note: See Pages 10 and 11 for Vent Termination Requirements
Listed Rain Cap
Wall Straps
Required Every
4 Feet Minimum
Figure 20 -
Listed Rain Cap
Optional
Clean-Out
Access Door
Figure 21 -
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
Maintain clearances
specified by vent
manufacturer
Vertical Vent Through the Roof
Existing
Chimney Pipe
Pipe Increaser
Maintain clearances
specified by vent
manufacturer
Interior Vertical Vent into an Existing Class A Chimney
Listed Rain Cap
Flashing
Clean-Out
Tee
Listed Rain Cap
Extend Pipe to the Top
if Existing Chimney is
Corroded or Damaged