INSTALLATION & INITIAL SETUP
Tension on the carriage is adjustable for differing types of dinnerware
by connecting , disconnecting or substituting carriage springs:
1. Remove the open tube assembly of shielded dispensers from the
shield. Stand the open tube assembly upright and secure it to
prevent tipping.
2. Test the spring tension by stacking 10 pieces of dinnerware on the
carriage and noting the position of the top piece.
3. Disconnect or substitute carriage springs until the right combination
is found to allow the top piece of dinnerware to be raised just high
enough to be easily picked from the dispenser. In order to allow the
carriage to stay level and operate smoothly, be sure to make the
same changes to all four sections of carriage springs.
NOTE: There are two different tension springs. Coarse and fine
springs are visually nearly identical, but the difference in tension
can be felt by carefully stretching them.
NOTE: Springs for heated and non-heated units are different,
and should not be mixed in the same dispenser.
Additional springs are available through your Authorized Wells
Service Agency.
4. Disconnect unused springs from the lower retaining bracket and
allow them to dangle. They will remain out of the way, but
available if adjustments are later required.
Heated dispensers are factory set at 120ºF. The temperature may be
adjusted by turning the temperature adjustment: clockwise to increase
temperature, or counter-clockwise to decrease temperature.
For unshielded dispensers, carefully slide the open tube into the cutout
in the counter.
For shielded and heated dispensers, carefully slide the shield into the
cutout in the counter and attach with the supplied mounting hardware.
Carefully slide the open tube into the shield.
Plug the power cord of heated dispensers into electrical power.
INSTALLATION (continued)
5
CAUTION:
Hot Surface
Exposed surfaces of heated
dispensers can be hot to the
touch and may cause burns.
Disconnect dispenser from
electrical power and allow to
cool before removing open
tube assembly from shield.
PLATE IN
POSITION
CARRIAGE
SPRINGS
Fig. 2 Carriage Tension
Adjustment
TEMPERATURE
ADJUSTMENT
POWER
SWITCH
INSIDE TUBE
Fig. 3 Temperature